{"product_id":"abb-advant-ocs-and-advant-800xa-5shx1445h0002-3bhl000387r0101-3bhb003386r0101-5sxe05-0153-igct-module","title":"ABB 5SHX1445H0002 3BHL000387R0101 IGCT Power Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe ABB 5SHX1445H0002 (3BHL000387R0101) is a high-performance Integrated Gate-Commutated Thyristor (IGCT) power semiconductor module designed for demanding industrial power electronics. This assembly integrates the 5SHX1445H0002 asymmetric reverse-conducting IGCT thyristor chip with the 3BHB003386R0101 (5SXE05-0153) gate driver unit in a single, robust press-pack package. By combining the high-speed switching of IGBTs with the low conduction losses and high blocking voltage of GTO thyristors, this module is optimized for medium-voltage drive systems and high-power converters.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eHigh-power IGCT switching module for 4.5 kV-class medium-voltage applications.\u003c\/li\u003e\n\u003cli\u003eIntegrated gate driver unit (5SXE05-0153) for precise, high-current gate control pulses.\u003c\/li\u003e\n\u003cli\u003eFiber optic communication for galvanic isolation between control and power layers.\u003c\/li\u003e\n\u003cli\u003eLow conduction and switching losses with fast turn-off characteristics.\u003c\/li\u003e\n\u003cli\u003eRobust press-pack housing designed for integration into water-cooled stacks.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eMedium-voltage motor drives (e.g., ACS6000, PCS6000 platforms).\u003c\/li\u003e\n\u003cli\u003eHVDC transmission and grid stabilization systems.\u003c\/li\u003e\n\u003cli\u003eMarine propulsion systems and heavy industrial converters.\u003c\/li\u003e\n\u003cli\u003eRail transport propulsion and auxiliary power converters.\u003c\/li\u003e\n\u003cli\u003eWind turbine power conversion stages.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e5SHX1445H0002 \/ 3BHL000387R0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGate Unit\u003c\/td\u003e\n\u003ctd\u003e5SXE05-0153 \/ 3BHB003386R0101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Blocking Voltage (VDRM\/VRRM)\u003c\/td\u003e\n\u003ctd\u003e4,500 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Current (IT(AV))\u003c\/td\u003e\n\u003ctd\u003e1,445 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeak Forward Current\u003c\/td\u003e\n\u003ctd\u003e2,200 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConduction Voltage Drop\u003c\/td\u003e\n\u003ctd\u003e2.5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurn-off Time\u003c\/td\u003e\n\u003ctd\u003e≤ 1 µs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGate Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e+15 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGate Trigger Current\u003c\/td\u003e\n\u003ctd\u003e0.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShort-Circuit Withstand\u003c\/td\u003e\n\u003ctd\u003e10 kA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermal Resistance (Rth(j-c))\u003c\/td\u003e\n\u003ctd\u003e0.1 degC\/W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Junction Temperature\u003c\/td\u003e\n\u003ctd\u003e150 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling:\u003c\/strong\u003e Handle the press-pack housing by the edges only. Do not touch the ceramic collar or copper pole faces with bare hands to avoid oil and contamination.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAlignment:\u003c\/strong\u003e Ensure perfect alignment of the IGCT between the upper and lower water-cooled heat sinks.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eClamping Force:\u003c\/strong\u003e This device requires a strict, uniform clamping force (typically 40 kN). Use a calibrated torque wrench or hydraulic press to tighten the stack spring according to the specific ABB hardware manual.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCooling:\u003c\/strong\u003e Thermal management requires efficient water cooling or an appropriate heatsink to maintain junction temperatures within rated limits.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is this 5SHX1445H0002?\u003c\/h3\u003e\u003cp\u003eIt is a high-performance semiconductor switching module that combines a central power thyristor wafer with an integrated, closely coupled gate driver board.\u003c\/p\u003e\u003ch3\u003eWhat are its primary voltage and current ratings?\u003c\/h3\u003e\u003cp\u003eThe module is rated for a peak voltage class of 4500 V (4.5 kV) and a continuous anode current threshold of 1445 A.\u003c\/p\u003e\u003ch3\u003eHow does the gate driver communicate with the main control rack?\u003c\/h3\u003e\u003cp\u003eThe integrated gate unit communicates using fiber optic links, which provides absolute galvanic isolation and safeguards low-voltage control layers from the high-voltage power paths.\u003c\/p\u003e\u003ch3\u003eWhat are the mechanical mounting constraints?\u003c\/h3\u003e\u003cp\u003eBecause it uses a standard press-pack configuration, it requires a precise and uniform clamping force of 40 kN. Incorrect mounting force will lead to irregular parallel contact resistance profiles and potential component failure.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50953284518140,"sku":"5SHX1445H0002 3BHL000387R0101 3BHB003386R0101 5SXE05-0153","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_81a283b1-ef9b-4da5-915c-7aa750f1a8e5.jpg?v=1786238989","url":"https:\/\/www.electronicplc.com\/ar\/products\/abb-advant-ocs-and-advant-800xa-5shx1445h0002-3bhl000387r0101-3bhb003386r0101-5sxe05-0153-igct-module","provider":"Electronic PLC","version":"1.0","type":"link"}