{"product_id":"abb-advant-s800-i-o-ai830a-3bse040662r1-analog-input-module-rtd","title":"ABB AI830A 3BSE040662R1 S800 I\/O Analog Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe ABB AI830A (3BSE040662R1) is a high-performance analog input module designed for the S800 I\/O system. This module provides 8 channels specifically configured for Resistance Temperature Detector (RTD) inputs, supporting various sensor types including Pt100, Cu10, Ni100, and Ni120, as well as resistive inputs. It is engineered for industrial environments requiring precise temperature monitoring and reliable signal acquisition.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e8 isolated input channels for RTD and resistive sensors.\u003c\/li\u003e\n\u003cli\u003eSupports 3-wire connection configurations for enhanced accuracy.\u003c\/li\u003e\n\u003cli\u003e14-bit resolution for high-precision data conversion.\u003c\/li\u003e\n\u003cli\u003eIntegrated diagnostic monitoring for open-circuit, short-circuit, and grounded sensor detection.\u003c\/li\u003e\n\u003cli\u003eHigh noise immunity with \u0026gt;120 dB CMRR and \u0026gt;60 dB NMRR.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe AI830A is primarily utilized in process automation systems, such as the ABB 800xA, for temperature measurement in industrial plants. It is suitable for applications involving heat exchangers, boilers, turbines, and other process equipment where RTD sensors are deployed to ensure operational safety and process control.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eAI830A (3BSE040662R1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Types\u003c\/td\u003e\n\u003ctd\u003ePt100, Cu10, Ni100, Ni120, Resistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e14 Bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCMRR (50Hz, 60Hz)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;120 dB (at 10 Ohm load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNMRR (50Hz, 60Hz)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;60 dB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Insulation Voltage\u003c\/td\u003e\n\u003ctd\u003e50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDielectric Test Voltage\u003c\/td\u003e\n\u003ctd\u003e500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e1.6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption (+5V)\u003c\/td\u003e\n\u003ctd\u003e70 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption (+24V)\u003c\/td\u003e\n\u003ctd\u003e50 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the S800 I\/O station power is disconnected before installing or removing the module from the mounting base.\u003c\/li\u003e\n\u003cli\u003eThe module is designed for DIN-rail mounting; ensure it is securely seated in the terminal base.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for RTD inputs to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices for the S800 I\/O rack to ensure signal integrity.\u003c\/li\u003e\n\u003cli\u003eHandle the module using ESD-safe procedures to prevent damage to internal electronic components.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat sensor types are compatible with the AI830A?\u003c\/h3\u003e\u003cp\u003eThe AI830A supports Pt100, Cu10, Ni100, and Ni120 RTD sensors, as well as general resistive inputs and potentiometers.\u003c\/p\u003e\u003ch3\u003eDoes this module support 2-wire or 3-wire sensors?\u003c\/h3\u003e\u003cp\u003eThe module is designed for 3-wire RTD connections to provide compensation for lead resistance.\u003c\/p\u003e\u003ch3\u003eWhat is the primary function of the diagnostic features?\u003c\/h3\u003e\u003cp\u003eThe module continuously monitors for open-circuit, short-circuit, and ground faults on the input channels to provide early warning of sensor failure or wiring issues, which is critical for maintaining process uptime.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50920066646268,"sku":"AI830A 3BSE040662R1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_ec94545c-de98-4cca-b91a-3aef8ca75385.jpg?v=1785913572","url":"https:\/\/www.electronicplc.com\/ar\/products\/abb-advant-s800-i-o-ai830a-3bse040662r1-analog-input-module-rtd","provider":"Electronic PLC","version":"1.0","type":"link"}