{"product_id":"abb-procontrol-p14-gjr2393100r1200-88ft05c-e-coupling-module","title":"ABB GJR2393100R1200 88FT05C-E Procontrol P14 Coupling Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe ABB GJR2393100R1200 (88FT05C-E) is a specialized Remote-Bus Coupling Module designed for the ABB Procontrol P14 and System 800xA distributed control environments. This module serves as a critical interface, facilitating reliable communication and data exchange between local station buses and remote bus networks. It is engineered to maintain high-speed, deterministic data throughput required for complex industrial automation and safety-critical applications.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned for integration within the Procontrol P14 platform.\u003c\/li\u003e\n\u003cli\u003eFunctions as a station modem and bus coupling module (88TK05 compatibility).\u003c\/li\u003e\n\u003cli\u003eHigh-speed communication interface for distributed control stations.\u003c\/li\u003e\n\u003cli\u003eRobust design suitable for demanding industrial environments.\u003c\/li\u003e\n\u003cli\u003eSupports seamless data exchange across remote bus architectures.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Power Plants:\u003c\/strong\u003e Distributed control systems for gas-fired power generation units.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNuclear and Hydroelectric:\u003c\/strong\u003e Control network management for conventional islands and power generation infrastructure.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMetallurgy and Steel:\u003c\/strong\u003e Interface for blast furnaces, converters, and continuous casting equipment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePetrochemical Industry:\u003c\/strong\u003e Distributed control for large-scale oil refining and ethylene production facilities.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eGJR2393100R1200 \/ 88FT05C-E\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManufacturer\u003c\/td\u003e\n\u003ctd\u003eABB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eProcontrol P14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24V DC +\/- 20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15W (typical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLatency\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;100 microseconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +85 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e5-95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is completely disconnected before installing or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eMount the module in a clean, dry, and well-ventilated cabinet to maintain the specified operating temperature range.\u003c\/li\u003e\n\u003cli\u003eUse shielded communication cables to minimize electromagnetic interference (EMI) in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is securely seated in the rack backplane to ensure proper electrical contact.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD (Electrostatic Discharge) precautions when handling the module to protect internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the GJR2393100R1200?\u003c\/h3\u003e\u003cp\u003eThis module acts as a data bridge, enabling communication between the local station bus and remote bus networks within the ABB Procontrol P14 system.\u003c\/p\u003e\u003ch3\u003eIs this module compatible with System 800xA?\u003c\/h3\u003e\u003cp\u003eYes, it is designed for use within ABB Procontrol P14 and System 800xA distributed control system architectures.\u003c\/p\u003e\u003ch3\u003eWhat are the environmental limits for this module?\u003c\/h3\u003e\u003cp\u003eThe module is rated for operation between -40 degC and +70 degC with a humidity range of 5-95% non-condensing.\u003c\/p\u003e","brand":"ABB","offers":[{"title":"Default Title","offer_id":50915035939068,"sku":"GJR2393100R1200 88FT05C-E","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_ed5f4ae7-e050-4435-b2a5-8c0971f16aeb.jpg?v=1785807772","url":"https:\/\/www.electronicplc.com\/ar\/products\/abb-procontrol-p14-gjr2393100r1200-88ft05c-e-coupling-module","provider":"Electronic PLC","version":"1.0","type":"link"}