{"product_id":"aip827-2-yokogawa-operation-keyboard-datasheet-technical-manual","title":"AIP827-2 Yokogawa Operation Keyboard | Datasheet \u0026 Technical Manual","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa AIP827-2\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAIP827\u003c\/strong\u003e Operation Keyboard, operates as a dedicated hardware component for Human Interface Station (HIS) input control within industrial automation environments. Configured for high-durability service in process control systems, the \u003cstrong\u003eYokogawa AIP827-2\u003c\/strong\u003e (\u003cstrong\u003eAIP827\u003c\/strong\u003e Operation Keyboard) provides direct physical signal execution via a dust-proof and drip-proof flat membrane interface, facilitating operator interaction through a standard QWERTY layout.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAIP827-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e44 cm x 28.4 cm x 5.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e5 deg C to 40 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e20 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100-120 VAC or 220-240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eUSB A-type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eYokogawa DCS Integration and Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe AIP827-2 utilizes a discrete USB A-type interface to transmit operator inputs to the HIS. The module maintains signal integrity through a robust, sealed chassis design, preventing the ingress of particulate matter and moisture in harsh industrial zones. The system architecture supports dual voltage input ranges, ensuring compatibility with varying plant power distribution infrastructures. The keyboard assembly incorporates channel-to-channel isolation principles within the integrated AC power adapter, protecting the internal logic circuits from transients commonly present on industrial AC lines.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the AIP827-2 keyboard compatible with hot-plugging during HIS operation?\u003c\/p\u003e\n\u003cp\u003eA: While the USB interface supports standard enumeration, it is advised to perform connections while the HIS is in a stable state to ensure the driver stack correctly identifies the peripheral as the primary input device.\u003c\/p\u003e\n\u003cp\u003eQ: How does the dust- and drip-proof design affect cleaning and maintenance?\u003c\/p\u003e\n\u003cp\u003eA: The flat-key design allows for surface-level cleaning using non-abrasive, lint-free cloths. Avoid using solvent-based cleaners that may compromise the integrity of the membrane seal or the Munsell-specified chassis finish.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the keyboard on a level surface at the operator console to ensure ergonomic stability and prevent mechanical strain on the USB cable connection.\u003c\/li\u003e\n\u003cli\u003eConnect the included AC adapter to a properly grounded outlet matching the 100-120 VAC or 220-240 VAC specifications; ensure the power cable is routed away from high-current EMI sources to prevent potential signal jitter.\u003c\/li\u003e\n\u003cli\u003eVerify the environmental conditions remain within 5 deg C to 40 deg C operating limits; storage exceeding 60 deg C may cause premature degradation of the membrane switch tactile feedback.\u003c\/li\u003e\n\u003cli\u003eEnsure the USB cable is secured with strain relief to prevent accidental disconnection from the HIS during critical control operations.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49171760677116,"sku":"AIP827-2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AIP827-21.jpg?v=1780882795","url":"https:\/\/www.electronicplc.com\/ar\/products\/aip827-2-yokogawa-operation-keyboard-datasheet-technical-manual","provider":"Electronic PLC","version":"1.0","type":"link"}