{"product_id":"allen-bradley-1756-a10xt-extreme-environment-chassis","title":"Allen-Bradley 1756-A10XT ControlLogix Extreme Environment 10-Slot Chassis","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Allen-Bradley 1756-A10XT is a 10-slot backplane chassis engineered for the ControlLogix Extreme Environment (XT) series. This ruggedized hardware is specifically designed to maintain operational integrity in demanding industrial applications characterized by corrosive atmospheres, extreme temperature variations, and high levels of vibration. It serves as the foundational backplane for mounting ControlLogix processors, communication modules, and I\/O modules in environments where standard-grade equipment may be susceptible to failure.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eExtreme Environment Design:\u003c\/strong\u003e Built to withstand harsh conditions, including exposure to corrosive gases and rapid thermal cycling.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Density Slot Configuration:\u003c\/strong\u003e Provides 10 slots for flexible system architecture and module expansion.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAdvanced ESD Protection:\u003c\/strong\u003e Rated for 6 kV contact discharge and 8 kV air discharge to prevent damage from static buildup.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Location Compatibility:\u003c\/strong\u003e Suitable for deployment in ATEX-certified Zone 2 hazardous areas.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Resilience:\u003c\/strong\u003e Operates reliably in humidity levels ranging from 5% to 95% (non-condensing).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eControlLogix XT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Slots\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Style\u003c\/td\u003e\n\u003ctd\u003eHorizontal (Rear panel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eConvection (Vertical airflow)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eESD Protection\u003c\/td\u003e\n\u003ctd\u003e6 kV contact \/ 8 kV air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Type\u003c\/td\u003e\n\u003ctd\u003eOpen-type\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.91 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Ensure the chassis is mounted horizontally on a flat, rigid surface to maintain structural alignment.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eAirflow:\u003c\/strong\u003e Maintain adequate clearance above and below the chassis to allow for effective convection cooling; do not obstruct the vertical airflow path.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Connect the chassis to a reliable, low-impedance earth ground to ensure proper shielding and ESD protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eModule Insertion:\u003c\/strong\u003e Always power down the system before inserting or removing modules to prevent electrical arcing or damage to the backplane pins.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e While designed for extreme environments, ensure the installation location remains within the specified temperature and humidity ranges to prolong service life.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs the 1756-A10XT compatible with standard ControlLogix modules?\u003c\/h3\u003e\u003cp\u003eYes, the 1756-A10XT is compatible with standard Bulletin 1756 I\/O modules, processors, and communication bridges, allowing for seamless integration into existing ControlLogix architectures.\u003c\/p\u003e\u003ch3\u003eWhat does the XT designation mean?\u003c\/h3\u003e\u003cp\u003eThe XT designation indicates that the module is part of the Allen-Bradley Extreme Environment product line, which features enhanced protection against environmental stressors such as corrosive gases, high humidity, and extreme temperatures compared to standard-grade components.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":51002172014844,"sku":"1756-A10XT","price":56.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_725552bf-fbb1-4f63-99b4-30c095229211.jpg?v=1787336189","url":"https:\/\/www.electronicplc.com\/ar\/products\/allen-bradley-1756-a10xt-extreme-environment-chassis","provider":"Electronic PLC","version":"1.0","type":"link"}