{"product_id":"allen-bradley-panelview-2711-k6c2l1-operator-interface","title":"Allen-Bradley 2711-K6C2L1 PanelView 600 Operator Interface","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Allen-Bradley 2711-K6C2L1 is a PanelView Standard 600 operator terminal designed for real-time machine monitoring and control. This Human-Machine Interface (HMI) features a 5.7-inch color active matrix TFT display with a resolution of 320 x 234 pixels. It provides a robust, tactile keypad interface suitable for industrial environments where touchscreen operation may be impractical. This specific model utilizes DH-485 communication and supports a 24V DC power input.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e5.7-inch color active matrix TFT display.\u003c\/li\u003e\n\u003cli\u003eTactile keypad input with 10 configurable function keys, numeric keypad, and navigation buttons.\u003c\/li\u003e\n\u003cli\u003eRated for up to 1 million actuations per key.\u003c\/li\u003e\n\u003cli\u003eField-replaceable backlight with 50,000-hour expected half-life.\u003c\/li\u003e\n\u003cli\u003eSupports DH-485 communication protocol.\u003c\/li\u003e\n\u003cli\u003eField-replaceable internal battery for real-time clock and memory retention.\u003c\/li\u003e\n\u003cli\u003eCompatible with various enhancement modules, including memory cards and anti-glare overlays.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eAutomotive: Real-time monitoring for robotic cells, welding, and stamping lines.\u003c\/li\u003e\n\u003cli\u003eFood and Beverage: Suitable for packaging, bottling, and heat-sealing applications.\u003c\/li\u003e\n\u003cli\u003eWater and Wastewater: Localized control for filtration, pumping, and dosing systems.\u003c\/li\u003e\n\u003cli\u003ePharmaceutical and Chemical: Batch processing and reactor vessel monitoring.\u003c\/li\u003e\n\u003cli\u003ePulp and Paper: Reliable operation in high-vibration machinery environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e2711-K6C2L1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Type\u003c\/td\u003e\n\u003ctd\u003eColor Active Matrix TFT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e320 x 234 pixels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage (DC)\u003c\/td\u003e\n\u003ctd\u003e18-32V DC (24V DC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption (DC)\u003c\/td\u003e\n\u003ctd\u003e34W max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication\u003c\/td\u003e\n\u003ctd\u003eDH-485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinter Port\u003c\/td\u003e\n\u003ctd\u003eRS-232 (1200, 2400, 9600, 19,200 Kbps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003e10 Function keys + numeric\/navigation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the panel cutout is prepared according to the manufacturer's mounting template to maintain NEMA\/IP seal integrity.\u003c\/li\u003e\n\u003cli\u003eUse appropriate gasket seals when mounting in NEMA 4X enclosures to prevent moisture ingress.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around the unit for ventilation and to prevent overheating.\u003c\/li\u003e\n\u003cli\u003eRoute communication cables away from high-voltage lines and sources of electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eAlways power down the terminal before inserting or removing memory modules or performing maintenance.\u003c\/li\u003e\n\u003cli\u003eEnsure the unit is properly grounded to the enclosure chassis to mitigate electrical noise.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the primary communication method for the 2711-K6C2L1?\u003c\/h3\u003e\u003cp\u003eThis terminal uses the DH-485 communication protocol for both application transfers and network integration.\u003c\/p\u003e\u003ch3\u003eCan I use the RS-232 port for programming?\u003c\/h3\u003e\u003cp\u003eNo, the RS-232 port on this specific model is dedicated to printing functions. Application uploads and downloads must be performed via the DH-485 port.\u003c\/p\u003e\u003ch3\u003eIs the backlight replaceable?\u003c\/h3\u003e\u003cp\u003eYes, the unit features a field-replaceable backlight designed for a 50,000-hour service life.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":50912215990524,"sku":"2711-K6C2L1","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_c179cf0a-2fda-4214-bf35-dc3b6ac5cd2e.jpg?v=1785734749","url":"https:\/\/www.electronicplc.com\/ar\/products\/allen-bradley-panelview-2711-k6c2l1-operator-interface","provider":"Electronic PLC","version":"1.0","type":"link"}