{"product_id":"analog-input-module-yokogawa-f3ad04-5v","title":"Analog Input Module YOKOGAWA F3AD04-5V","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYOKOGAWA F3AD04-5V\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eF3AD04\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eanalog input module, operates as a dedicated hardware component for high-density analog signal acquisition within F3 series programmable logic controller platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eF3\u003c\/strong\u003e: Series prefix indicating compatibility with standard F3 backplane rack systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAD\u003c\/strong\u003e: Analog-to-digital input function designation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e04\u003c\/strong\u003e: Four differential input channels configuration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e5V\u003c\/strong\u003e: 5 VDC backplane power supply operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eF3AD04-5V\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYOKOGAWA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSingapore\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0.2 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e28.9 mm (W) x 100 mm (H) x 106.1 mm (D)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e0 deg C to 55 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 VDC nominal\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4 Differential\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eDeterministic Network Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe F3AD04-5V is engineered for integration into deterministic control networks, ensuring precise timing for analog-to-digital conversion cycles. The module architecture supports high-speed backplane bus communication, enabling the PLC processor to synchronize data acquisition with real-time logic execution. The design utilizes high-impedance differential inputs to minimize loading effects on field instrumentation, maintaining signal accuracy in complex I\/O density scaling applications.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the F3AD04-5V support hot-swapping on the F3 backplane?\u003c\/p\u003e\n\u003cp\u003eA: No, the module does not support hot-swapping. The rack power must be cycled off prior to module insertion or removal to prevent electrical arcing and backplane bus communication errors.\u003c\/p\u003e\n\u003cp\u003eQ: Are the four differential input channels electrically isolated from each other?\u003c\/p\u003e\n\u003cp\u003eA: The F3AD04-5V features differential inputs; however, consult the technical manual for specific galvanic isolation ratings. In applications with high common-mode voltages, external signal isolators are required to protect the module input circuitry.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify that the F3 base rack is properly grounded to the cabinet's protective earth bus to ensure electromagnetic compatibility and personnel safety.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlign the module with the intended slot guides on the backplane rack. Apply consistent pressure until the module is fully seated and the locking lever is engaged.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFor differential signals, connect both the positive and negative signal leads to the designated terminal block. Ensure that twisted-pair, shielded cabling is utilized to minimize EMI.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGround the cable shield at a single termination point, preferably at the cabinet's instrument earth bar, to prevent ground loops that could introduce signal noise.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAfter installation, perform a software configuration check to ensure the CPU accurately maps the input channels and that the converted digital values correlate to the field signal levels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49257829695740,"sku":"F3AD04-5V","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/F3AD04-5V1.jpg?v=1783388621","url":"https:\/\/www.electronicplc.com\/ar\/products\/analog-input-module-yokogawa-f3ad04-5v","provider":"Electronic PLC","version":"1.0","type":"link"}