{"product_id":"analog-input-module-yokogawa-sai143-s63","title":"Analog Input Module YOKOGAWA SAI143-S63","description":"\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA SAI143-S63\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSAI143\u003c\/strong\u003e Analog Input Module, operates as a dedicated hardware component for 16-channel analog current signal acquisition within Yokogawa CENTUM VP and ProSafe-RS control system platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe SAI143-S63 utilizes a standardized suffix configuration for hardware version control. The -S63 designator identifies the module as a high-density input unit compliant with specific safety and environment-hardened standards required for operation in integrated DCS\/SIS control environments.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSAI143-S63\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.2 cm x 10.7 cm x 13 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e5 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 (isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAllowable Input Current\u003c\/td\u003e\n\u003ctd\u003e24 mA max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V AC (1 minute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Analog Signal Processing\u003c\/h3\u003e\n\u003cp\u003eThe SAI143-S63 is engineered with robust galvanic isolation between the field input stage and the internal system bus. This isolation is required to prevent ground potential interference and suppress electrical transients originating from field-side instrumentation. The module facilitates accurate 4-20 mA current monitoring while maintaining compliance with rigorous industrial control standards. By providing independent isolation for each of the 16 channels, the module ensures that electrical faults in one loop do not propagate to the control system backplane.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the SAI143-S63 require external loop power?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module is designed to receive 4-20 mA input signals. The field instruments must be powered via an external 24 VDC source or through an appropriate terminal board that supplies loop power to the field devices.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module compatible with HART loop protocol devices?\u003c\/p\u003e\n\u003cp\u003eA: The SAI143-S63 is designed to pass 4-20 mA signals. When used in conjunction with specific Yokogawa terminal boards or HART-enabled interface modules, it can facilitate HART signal communication between field devices and the DCS.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eRack Mounting: Ensure the module is fully seated into the corresponding terminal board or base unit. Secure the front-panel locking mechanisms to guarantee consistent electrical contact with the system bus.\u003c\/li\u003e\n\u003cli\u003eGrounding and Shielding: Terminate signal cable shields at the cabinet ground bus. Proper shield termination is required to maintain the effectiveness of the 1500 V AC isolation barrier against electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eWiring Precautions: Use twisted-pair cabling for all 4-20 mA loops to minimize inductive crosstalk. Ensure that the wire gauge is compatible with the pressure clamp terminals of the base interface unit.\u003c\/li\u003e\n\u003cli\u003eThermal Management: Ensure adequate spacing between modules to facilitate convective heat dissipation. Maintain the operating ambient temperature within the -20 deg C to 70 deg C range to prevent measurement drift and hardware fatigue.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49235766214908,"sku":"SAI143-S63","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/SAI143-S63.jpg?v=1782696710","url":"https:\/\/www.electronicplc.com\/ar\/products\/analog-input-module-yokogawa-sai143-s63","provider":"Electronic PLC","version":"1.0","type":"link"}