{"product_id":"as1133-h00-yokogawa-analog-input-module-new-original-stock","title":"AS1133-H00 Yokogawa Analog Input Module | New \u0026 Original Stock","description":"\u003cp\u003eConfigured for analog signal acquisition in Field Integrated Operation (FIO) platforms, the \u003cstrong\u003eYokogawa AS1133-H00\u003c\/strong\u003e (\u003cstrong\u003eAS1133-H00\u003c\/strong\u003e Analog Input Module) provides direct physical\/electrical execution of 8-channel 4-20 mA input sensing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAS1133-H00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e3.8 cm x 12.7 cm x 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eIndustrial grade (consult FIO system manual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eRefer to FIO system power budget\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eChannel-to-channel isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and Signal Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module functions as an interface for field-mounted transmitters, including pressure transducers, temperature sensors, and flow meters. To maintain process data integrity in demanding environments, the design utilizes channel-to-channel isolation, which mitigates common-mode noise and ground loops between disparate field loops. The integrated safety barrier design supports deployment in hazardous area installations, providing intrinsic protection for the field side while maintaining high-resolution signal conversion for the FIO control bus.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the integrated safety barrier design require additional external barriers for hazardous zone deployment?\u003c\/p\u003e\n\u003cp\u003eA: The module is engineered with built-in safety barrier functionality. Verify that the specific hazardous area classification and zone requirements match the module's safety rating as documented in the technical manual.\u003c\/p\u003e\n\u003cp\u003eQ: Can these channels be configured for voltage inputs in addition to 4-20 mA?\u003c\/p\u003e\n\u003cp\u003eA: The hardware architecture is optimized for 4-20 mA current loop sensing. Refer to the system configuration guide to determine if shunt resistors or alternative software-defined modes support voltage input ranges.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the FIO system power is disconnected before installing the module into the baseplate to prevent electrical transients.\u003c\/li\u003e\n\u003cli\u003eTerminate all 4-20 mA loops using shielded, twisted-pair cabling to maintain high noise immunity across the isolated channels.\u003c\/li\u003e\n\u003cli\u003eVerify that the cable shield is connected to the designated ground rail on the FIO rack to optimize the effectiveness of the channel isolation.\u003c\/li\u003e\n\u003cli\u003eConfirm that the field devices are correctly powered within their specific operational voltage requirements, as the module acts as a current loop receiver.\u003c\/li\u003e\n\u003cli\u003ePerform an analog input loop test using a calibrated 4-20 mA source to confirm channel mapping and accuracy within the control system software.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49174440444156,"sku":"ASI133-H00","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/ASI133-H002.jpg?v=1780971137","url":"https:\/\/www.electronicplc.com\/ar\/products\/as1133-h00-yokogawa-analog-input-module-new-original-stock","provider":"Electronic PLC","version":"1.0","type":"link"}