{"product_id":"bently-nevada-330850-50-05-proximitor-sensor-3","title":"Bently Nevada 330180-50-00 3300 XL Proximitor Sensor","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Bently Nevada 330180-50-00 is a 3300 XL Proximitor Sensor designed for use with the 3300 XL 8 mm Proximity Transducer System. This signal conditioning module receives signals from a compatible proximity probe and extension cable, converting eddy-current measurements into a calibrated voltage output proportional to the gap between the probe tip and the target surface. It is a critical component for continuous condition monitoring and machinery protection in rotating equipment.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDesigned for 5.0-meter (16.4-foot) system length applications.\u003c\/li\u003e\n\u003cli\u003eProvides a calibrated output of 7.87 V\/mm (200 mV\/mil).\u003c\/li\u003e\n\u003cli\u003eHigh immunity to radio frequency interference (RFI) and electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eCompatible with 3300 XL 8 mm and 5 mm proximity probes.\u003c\/li\u003e\n\u003cli\u003eSupports both DIN-rail and panel mounting configurations.\u003c\/li\u003e\n\u003cli\u003eElectrical isolation provided by the mounting base, eliminating the need for separate isolator plates.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eTurbomachinery: Steam turbines, gas turbines, and turbo-expanders.\u003c\/li\u003e\n\u003cli\u003eCompressors: Centrifugal, axial, and reciprocating process gas compressors.\u003c\/li\u003e\n\u003cli\u003eRotating Equipment: Industrial pumps, generators, motors, and fans.\u003c\/li\u003e\n\u003cli\u003eManufacturing: Extruders and pelletizers requiring precise shaft vibration and position monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e330180-50-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Length\u003c\/td\u003e\n\u003ctd\u003e5.0 meters (16.4 feet)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Sensitivity\u003c\/td\u003e\n\u003ctd\u003e7.87 V\/mm (200 mV\/mil)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinear Range\u003c\/td\u003e\n\u003ctd\u003e2.0 mm (80 mils)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Resistance\u003c\/td\u003e\n\u003ctd\u003e50 Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Gap Voltage\u003c\/td\u003e\n\u003ctd\u003e-10 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExtension Cable Capacitance\u003c\/td\u003e\n\u003ctd\u003e69.9 pF\/m (21.3 pF\/ft) typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Option\u003c\/td\u003e\n\u003ctd\u003ePanel Mount\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAgency Approval\u003c\/td\u003e\n\u003ctd\u003e00 (Not required)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system length (probe + extension cable + Proximitor sensor) is exactly 5.0 meters to maintain electrical calibration.\u003c\/li\u003e\n\u003cli\u003eThe module can be mounted on a standard DIN-rail or via a 4-hole panel mount footprint.\u003c\/li\u003e\n\u003cli\u003eEnsure the mounting location is free from excessive moisture and corrosive gases.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for signal transmission to maintain signal integrity in high-EMI environments.\u003c\/li\u003e\n\u003cli\u003eAlways power down the monitoring system before installing or removing the Proximitor sensor to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eVerify that the probe tip is correctly gapped according to the specific machinery requirements before commissioning.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the function of the 330180-50-00?\u003c\/h3\u003e\u003cp\u003eIt acts as the primary signal conditioner for the 3300 XL transducer system, converting non-contact eddy-current probe signals into a voltage output for vibration and position monitoring.\u003c\/p\u003e\u003ch3\u003eDoes this sensor require individual calibration?\u003c\/h3\u003e\u003cp\u003eNo. The 3300 XL system is designed for complete interchangeability, meaning individual components (probe, cable, sensor) do not require bench calibration when replaced.\u003c\/p\u003e\u003ch3\u003eCan this sensor be used in high-density installations?\u003c\/h3\u003e\u003cp\u003eYes, the physical design allows for compact mounting on DIN-rails or traditional panels, making it suitable for high-density cabinet layouts.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":50743066132732,"sku":"330180-50-00","price":70.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_a2db8314-5b42-4853-ae3d-0e6d7dba63d6.jpg?v=1785461228","url":"https:\/\/www.electronicplc.com\/ar\/products\/bently-nevada-330850-50-05-proximitor-sensor-3","provider":"Electronic PLC","version":"1.0","type":"link"}