{"product_id":"c65h-dcc6a-dc-miniature-circuit-breaker-10ka","title":"C65H-DCC6A DC Miniature Circuit Breaker 10kA","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric C65H-DCC6A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efunctions as a high-performance miniature circuit breaker (MCB) purpose-built for direct current (DC) applications. As a core component of the Multi 9 C65H series, this 2-pole breaker provides essential overload and short-circuit protection for low-voltage DC networks. It utilizes a thermal-magnetic tripping mechanism with a C-curve characteristic, specifically calibrated to handle moderate inrush currents while maintaining tight protection for sensitive electronics. We supply this unit as\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e100% Brand New and Original\u003c\/strong\u003e, ensuring critical safety for solar photovoltaic (PV) arrays, telecommunications infrastructure, and battery energy storage systems (BESS).\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eManufacturer\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eSchneider Electric\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC65H-DCC6A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eNumber of Poles\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e2P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Current (\u003cspan class=\"math-inline\"\u003e$I_n$\u003c\/span\u003e)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e6 A\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTripping Curve\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eC Curve\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eRated Operational Voltage (\u003cspan class=\"math-inline\"\u003e$U_e$\u003c\/span\u003e)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e250 V DC\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eBreaking Capacity (\u003cspan class=\"math-inline\"\u003e$I_{cu}$\u003c\/span\u003e)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10 kA at 250 V DC (IEC 60947-2)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eImpulse Withstand Voltage (\u003cspan class=\"math-inline\"\u003e$U_{imp}$\u003c\/span\u003e)\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e5 kV\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMechanical Endurance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20,000 cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eElectrical Endurance\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e10,000 cycles\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eMounting Support\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e35 mm symmetrical DIN rail\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eTerminal Capacity\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1 mm² to 25 mm² (Rigid cables)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-30 °C to +70 °C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003e\u003cstrong\u003eStandards\u003c\/strong\u003e\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eIEC 60947-2, IEC 60898-2\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eEngineering Advantages\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSuperior Arc Suppression:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eUnlike standard AC breakers, the C65H-DCC6A features specialized internal permanent magnets to pull DC arcs into the chutes. This design ensures rapid quenching of direct current arcs, which are naturally more difficult to extinguish than AC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized Renewable Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe C-curve characteristic perfectly balances the requirements of solar inverters and battery chargers. It prevents nuisance tripping during initial capacitor charging while responding instantaneously to short-circuit faults in the DC bus.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Environmental Resilience:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eThe module operates reliably across an extended temperature range from -30°C to +70°C. This thermal stability makes it ideal for outdoor-rated PV combiner boxes and unconditioned telecommunication shelters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompact DIN-Rail Efficiency:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eOccupying only 36mm of rail width, this breaker maximizes space within crowded control panels. The modular format allows for rapid integration with other Multi 9 accessories, such as auxiliary contacts and shunt trips.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQs\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDoes the C65H-DCC6A require specific polarity during wiring?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eYes. DC circuit breakers are polarity sensitive due to the magnetic arc-quenching design. You must follow the terminal markings (+\/-) indicated on the front or side of the device to ensure the arc is correctly directed into the arc chute during a fault. Failure to observe polarity can damage the breaker.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCan I use this 250V DC breaker for higher voltage solar strings?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis specific model is rated for 250V DC. If your solar array output or battery bank exceeds this operational voltage, you must utilize a higher-rated model or connect multiple poles in series as per Schneider’s technical wiring diagrams to increase the dielectric strength.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWhat is the breaking capacity of this unit?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe C65H-DCC6A provides a high breaking capacity of 10 kA. This rating ensures the breaker can safely interrupt high-magnitude fault currents without exploding or welding the contacts, protecting the downstream cables and expensive DC equipment.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":49080528568572,"sku":"C65H-DCC6A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/16_0dce82e5-f170-42a8-af7d-a4def3a54a2d.jpg?v=1778318003","url":"https:\/\/www.electronicplc.com\/ar\/products\/c65h-dcc6a-dc-miniature-circuit-breaker-10ka","provider":"Electronic PLC","version":"1.0","type":"link"}