{"product_id":"dc-input-module-yokogawa-f3xd64-3f","title":"DC Input Module Yokogawa F3XD64-3F","description":"\u003cp\u003eConfigured for high-density digital signal acquisition in FA-M3 programmable logic controller (PLC) network platforms, the \u003cstrong\u003eYokogawa F3XD64-3F\u003c\/strong\u003e (\u003cstrong\u003eF3XD64-3F\u003c\/strong\u003e DC Input Module) provides direct physical\/electrical execution. This 64-channel component serves as the primary \u003cstrong\u003eF3XD64-3F\u003c\/strong\u003e interface utilized to execute sensor and switch signal processing across industrial automation platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3XD64-3F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.31 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard FA-M3 module form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial ambient\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e75 mA (5 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e64 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003eSelectable (0 to 16 ms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003ePLC Control and Photocoupler Isolation\u003c\/h3\u003e\n\u003cp\u003eThe F3XD64-3F utilizes photocoupler isolation to ensure complete electrical separation between the field device signals and the PLC backplane bus. This architecture is critical for protecting the controller from noise and transients often encountered in large-scale machine control environments. The module supports selectable response times, allowing engineers to filter contact bounce or optimize signal throughput for specific high-speed applications. With a 100% simultaneous input rating, the module remains stable even when all 64 channels are active, maintaining reliable state transition detection for field sensors.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the response time be configured individually for each channel?\u003c\/p\u003e\n\u003cp\u003eA: The response time settings for the F3XD64-3F are typically applied per module. Ensure all connected field devices on the module share similar operational characteristics to maximize the effectiveness of the selected filter setting.\u003c\/p\u003e\n\u003cp\u003eQ: Is external power required for the digital input circuits?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the inputs are rated for a nominal 24 V DC signal. Ensure the external power supply for the field sensors is stable and within the 20.4 to 26.4 V DC operating range to prevent intermittent signal status.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnection:\u003c\/strong\u003e The module uses a 40-pin connector for all 64 channels. Use factory-specified pre-wired cables to ensure the correct mapping of signals and to maintain the integrity of the high-density connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e To minimize electromagnetic interference (EMI), route input signal cables in dedicated conduits or trays, keeping them physically separated from AC power lines and high-current motor drive cables.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Verify that the FA-M3 base unit is connected to a low-impedance earth ground. This provides a stable reference for the input circuits and ensures the effectiveness of the internal photocoupler protection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eInspection:\u003c\/strong\u003e Periodically check the 40-pin connector for any signs of loose pins or oxidation. Ensure the locking tabs are engaged to prevent disconnection due to vibration.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49240019435772,"sku":"F3XD64-3F","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/F3XD64-3F2.jpg?v=1782869610","url":"https:\/\/www.electronicplc.com\/ar\/products\/dc-input-module-yokogawa-f3xd64-3f","provider":"Electronic PLC","version":"1.0","type":"link"}