{"product_id":"duplexed-safety-control-unit-yokogawa-ssc50d-f2121","title":"Duplexed Safety Control Unit YOKOGAWA SSC50D-F2121","description":"\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA SSC50D-F2121\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eSSC50D\u003c\/strong\u003e Safety Control Unit, operates as a dedicated hardware component for high-integrity logic execution within ProSafe-RS Safety Instrumented System (SIS) platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSSC50D-F2121\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003ejapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.3 cm x 5.1 cm x 5.4 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified (Redundant SIS Bus)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArchitecture\u003c\/td\u003e\n\u003ctd\u003eDuplexed (Redundant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Compliance\u003c\/td\u003e\n\u003ctd\u003eSIL3 compatible (ProSafe-RS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTriple Modular Redundancy (TMR) and Fail-Safe State Execution\u003c\/h3\u003e\n\u003cp\u003eThe SSC50D-F2121 is engineered for critical safety loops requiring TMR or duplexed redundancy to ensure continuous process protection. The control unit performs internal diagnostic synchronization, comparing inputs between redundant processing channels to detect discrepancies in real-time. In the event of a internal hardware fault or a loss of process data integrity, the unit triggers a fail-safe state execution, driving final control elements (such as emergency shutdown valves) to their predefined safe position. This architecture mitigates the risk of spurious trips while maintaining strict adherence to SIL3 safety requirements.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How is the duplexed synchronization managed during normal operation?\u003c\/p\u003e\n\u003cp\u003eA: The two controller modules exchange heartbeat and status data across a dedicated high-speed synchronization bus. This ensures that both units maintain an identical process image, allowing for bumpless switchover in the event of a primary processor fault.\u003c\/p\u003e\n\u003cp\u003eQ: Can the unit be configured for online configuration changes?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the duplexed architecture allows for limited online modifications to the control logic, provided the system is in a permitted state. However, major logic changes require the system to be placed in a maintenance or bypass mode to comply with site safety standards.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the unit in a clean, grounded control cabinet specifically designated for SIS hardware to avoid interference from non-safety-rated signals.\u003c\/li\u003e\n\u003cli\u003eVerify that the backplane connections are free of oxidation before seating the unit to ensure low-resistance communication paths for the synchronization bus.\u003c\/li\u003e\n\u003cli\u003eTerminate all redundant power and communication cables according to the system wiring diagrams, using labeled ferrules to maintain traceability.\u003c\/li\u003e\n\u003cli\u003ePerform an internal diagnostic self-test via the engineering workstation upon power-up to confirm that both processor channels are synchronized and in a \"Healthy\" state.\u003c\/li\u003e\n\u003cli\u003eBond the chassis to the cabinet’s protective earth bus using a high-conductivity braided strap to minimize potential differences between the controller and the process ground.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49260673040636,"sku":"SSC50D-F2121","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/SSC50D-F25241.jpg?v=1781143677","url":"https:\/\/www.electronicplc.com\/ar\/products\/duplexed-safety-control-unit-yokogawa-ssc50d-f2121","provider":"Electronic PLC","version":"1.0","type":"link"}