{"product_id":"emerson-deltav-kj1501x1-bc4-13p0063x052-power-supply-system","title":"Emerson DeltaV KJ1501X1-BC4 13P0063X052 System Power Supply","description":"\u003cp\u003eThe Emerson KJ1501X1-BC4 (13P0063X052) is a dual DC\/DC system power supply module engineered for the DeltaV M-Series distributed control system. This module provides stable, regulated power to controllers and I\/O cards mounted within a horizontal carrier assembly. It is designed to integrate into a 2-Wide Power\/Controller Carrier, supporting configurations for single power supply operation or redundant power setups.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDual DC\/DC power conversion for M-Series architecture.\u003c\/li\u003e\n\u003cli\u003eProvides combined output power of 10.2 W from +5.1 VDC and +3.4 VDC rails.\u003c\/li\u003e\n\u003cli\u003eDesigned for high-reliability operation in industrial control environments.\u003c\/li\u003e\n\u003cli\u003eIntegrated alarm contact for system monitoring.\u003c\/li\u003e\n\u003cli\u003eSupports operation in hazardous locations (Class I, Division 2).\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDistributed Control Systems (DCS) for process automation.\u003c\/li\u003e\n\u003cli\u003ePowering controllers for vibration and speed diagnostics in rotating machinery.\u003c\/li\u003e\n\u003cli\u003eSafety Instrumented Systems (SIS) logic solver support.\u003c\/li\u003e\n\u003cli\u003eModular process skids for water treatment and chemical processing.\u003c\/li\u003e\n\u003cli\u003eIndustrial HVAC and climate control systems.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ1501X1-BC4 (13P0063X052)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Rating\u003c\/td\u003e\n\u003ctd\u003e12 VDC at 13.8 A \/ 24 VDC at 4.5 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Rating\u003c\/td\u003e\n\u003ctd\u003e5.1 VDC at 2.0 A \/ 3.4 VDC at 2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Output Power\u003c\/td\u003e\n\u003ctd\u003e10.2 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Contact Rating\u003c\/td\u003e\n\u003ctd\u003e30 VDC at 2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 degC to +70 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Rating\u003c\/td\u003e\n\u003ctd\u003e10g, 1\/2 Sinewave, 11msec\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Rating\u003c\/td\u003e\n\u003ctd\u003e1mm P-P (2-13.2Hz); 0.7g (13.2-150Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower-Down Requirement:\u003c\/strong\u003e This module must not be inserted or removed while system power is energized. Ensure the carrier is de-energized before installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Safety:\u003c\/strong\u003e Verify that the environment is classified as safe before handling the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eVoltage Limits:\u003c\/strong\u003e In 12 VDC passthrough mode, the source must not exceed 12.6 VDC and must not exceed 16 A maximum.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaintenance:\u003c\/strong\u003e This unit contains no user-serviceable parts. Do not attempt to disassemble or repair.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e The module is factory-calibrated and requires no field adjustments during its service life.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the KJ1501X1-BC4?\u003c\/h3\u003e\u003cp\u003eThe KJ1501X1-BC4 is a system dual DC\/DC power supply module specifically designed to provide regulated voltage to DeltaV M-Series controllers and I\/O cards.\u003c\/p\u003e\u003ch3\u003eCan this module be hot-swapped?\u003c\/h3\u003e\u003cp\u003eNo. Unlike some other DeltaV components, this specific power supply module must not be inserted or removed while the system is powered.\u003c\/p\u003e\u003ch3\u003eWhat are the input power requirements for this unit?\u003c\/h3\u003e\u003cp\u003eWhen operating in 12 VDC passthrough mode, the input source must not exceed 12.6 VDC and must be limited to a maximum of 16 A.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":51015641235708,"sku":"KJ1501X1-BC4 13P0063X052","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_5b6ef166-d4c8-43f7-8e77-7c8fbfe35deb.jpg?v=1787769774","url":"https:\/\/www.electronicplc.com\/ar\/products\/emerson-deltav-kj1501x1-bc4-13p0063x052-power-supply-system","provider":"Electronic PLC","version":"1.0","type":"link"}