{"product_id":"emerson-deltav-kj3008x1-ba1-12p2293x052-digital-input-module","title":"Emerson DeltaV KJ3008X1-BA1 12P2293X052 Sequence of Events Digital Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Emerson DeltaV KJ3008X1-BA1 (part number 12P2293X052) is a high-performance Sequence of Events (SOE) digital input module designed for the DeltaV distributed control system. This module is engineered to capture and time-stamp discrete state changes at the source with millisecond precision, providing essential data for root-cause analysis during system transients, trips, or equipment failures. By recording the precise order of events, it enables rapid diagnostic resolution and helps minimize operational downtime in critical industrial processes.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh-Precision Time Stamping:\u003c\/strong\u003e Captures state changes with millisecond resolution for accurate event reconstruction.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHazardous Area Compatibility:\u003c\/strong\u003e Certified for Zone 2 (II 3 G \/ EEx nL IIC T4) environments.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eRobust Construction:\u003c\/strong\u003e Built to ISA-S71.04 Class G3 standards for resistance against corrosive airborne contaminants.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Keying:\u003c\/strong\u003e Features terminal block keying at position C5 to prevent improper module installation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHot-Swap Capability:\u003c\/strong\u003e Supports limited hot-insertion and removal when installed according to manufacturer guidelines and electrical constraints.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is widely utilized in high-stakes industrial environments where precise timing of discrete events is required for safety and operational efficiency, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003ePower Generation Plants\u003c\/li\u003e\n\u003cli\u003eOil and Gas Refineries\u003c\/li\u003e\n\u003cli\u003eChemical and Petrochemical Processing Facilities\u003c\/li\u003e\n\u003cli\u003eCritical Infrastructure Monitoring\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eEmerson\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKJ3008X1-BA1 (12P2293X052)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eSequence of Events (SOE) Digital Input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocalBus Power\u003c\/td\u003e\n\u003ctd\u003e12 VDC at 75 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBussed Field Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 75 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eField Circuit Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC at 5 mA per channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95 percent (Non-Condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Rating\u003c\/td\u003e\n\u003ctd\u003eIP 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShock Resistance\u003c\/td\u003e\n\u003ctd\u003e10 g (11 ms half-sinewave)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVibration Resistance\u003c\/td\u003e\n\u003ctd\u003e1 mm pk-pk (5-16 Hz); 0.5 g (16-150 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eNemko No. 02ATEX431U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eESD Precautions:\u003c\/strong\u003e Always use a grounded wrist strap or equivalent ESD protection when handling the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Requirements:\u003c\/strong\u003e Ensure field power is disconnected before physical handling of the module. Live removal is only permitted under specific conditions (e.g., using KJ1501X1-BC1 power supply and maintaining circuit inductance below 23 uH).\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Designed for installation on standard DeltaV carrier footprints. Ensure the mechanical keying at position C5 aligns correctly before seating.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironment:\u003c\/strong\u003e Ensure the installation area meets the specified temperature and humidity ranges and is protected from excessive vibration or corrosive environments beyond Class G3.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs this module user-serviceable?\u003c\/h3\u003e\u003cp\u003eNo, the KJ3008X1-BA1 contains no user-serviceable parts and is designed to be calibration-free. Any hardware failure requires a full unit replacement.\u003c\/p\u003e\u003ch3\u003eCan this module be removed while the system is running?\u003c\/h3\u003e\u003cp\u003eThe module supports limited hot-swapping. However, you must disconnect field power before removal, and ensure your system configuration meets the specific electrical requirements, such as circuit inductance limits, as defined in the DeltaV documentation.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":50644482621692,"sku":"KJ3008X1-BA1 12P2293X052","price":89.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_8dde2a89-f340-45b9-9dd3-02600c3c351a.jpg?v=1784965109","url":"https:\/\/www.electronicplc.com\/ar\/products\/emerson-deltav-kj3008x1-ba1-12p2293x052-digital-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}