{"product_id":"ex2100-series-is200eisbh1a-general-electric-exciter-isbus-board","title":"GE Fanuc IS200EISBH1A Exciter ISBus Board (EISB)","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc IS200EISBH1A is an Exciter ISBus Board (EISB) engineered for the EX2100 Excitation Control system. This specialized communication module facilitates high-speed data exchange between the system controllers (M1, M2, and C) and various peripheral diagnostic components. By managing the flow of critical feedback signals, the IS200EISBH1A plays a vital role in maintaining the operational stability of turbine generators in thermal and hydroelectric power generation environments, effectively minimizing the risk of over-excitation and protecting generator field windings.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eDedicated interface for EX2100 Excitation Control systems.\u003c\/li\u003e\n\u003cli\u003eSupports high-speed data transmission for redundant excitation topologies.\u003c\/li\u003e\n\u003cli\u003eProvides galvanic isolation between high-potential generator feedback and low-voltage control logic.\u003c\/li\u003e\n\u003cli\u003eIntegrates fiber-optic connectivity for reliable signal processing from EDCF boards.\u003c\/li\u003e\n\u003cli\u003eIncludes RS-232C serial communication support for diagnostic terminal access.\u003c\/li\u003e\n\u003cli\u003eCompact 3U single-slot module design for efficient rack density.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGeneral Electric (GE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIS200EISBH1A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eEX2100 Excitation Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eExciter ISBus Board (EISB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Span\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e0-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommon Mode Voltage\u003c\/td\u003e\n\u003ctd\u003e+\/- 5 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Lead Resistance\u003c\/td\u003e\n\u003ctd\u003e15 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7.5 W (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 to 65 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the control rack power is completely disconnected before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003eInstall the module in the designated slot, typically located directly below the DSPX controller.\u003c\/li\u003e\n\u003cli\u003eVerify that all fiber-optic and backplane connectors are fully seated to prevent intermittent communication errors.\u003c\/li\u003e\n\u003cli\u003eHandle the board using proper ESD (Electrostatic Discharge) precautions to protect sensitive internal components.\u003c\/li\u003e\n\u003cli\u003eRoute signal cables away from high-voltage power lines to minimize EMI interference.\u003c\/li\u003e\n\u003cli\u003eConfirm proper grounding of the control rack to maintain signal integrity for the 4-20 mA loops.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the IS200EISBH1A?\u003c\/strong\u003e\u003cbr\u003eIt serves as the communication bridge within the EX2100 system, routing feedback signals between the generator field and the digital signal processor to ensure precise excitation control.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eIs this module compatible with redundant systems?\u003c\/strong\u003e\u003cbr\u003eYes, the IS200EISBH1A is designed to support redundant excitation topologies to eliminate single points of failure in the communication network.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":51214913044732,"sku":"IS200EISBH1A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_ae3bf6a7-213e-4954-a02a-4260894fbad9.jpg?v=1788282324","url":"https:\/\/www.electronicplc.com\/ar\/products\/ex2100-series-is200eisbh1a-general-electric-exciter-isbus-board","provider":"Electronic PLC","version":"1.0","type":"link"}