{"product_id":"f3pu10-0n-power-supply-module-yokogawa","title":"F3PU10-0N Power Supply Module Yokogawa","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa F3PU10-0N\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF3PU10-0N\u003c\/strong\u003e Power Supply, operates as a dedicated hardware component for power distribution within FA-M3 programmable logic controller platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3PU10-0N\u003c\/strong\u003e: Base module designation for an AC-input power supply unit, specifically engineered for compatibility with 4-slot or 6-slot base units within the FA-M3 series.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3PU10-0N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003ejapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.19 kg (0.41 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e35 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100 to 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003e4-slot or 6-slot base modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and Power Bus Compatibility\u003c\/h3\u003e\n\u003cp\u003eThe F3PU10-0N provides deterministic voltage regulation to the backplane bus, ensuring stable DC supply to modular I\/O cards and CPU processors. The module architecture is designed to manage I\/O density scaling efficiently within smaller 4 or 6 slot backplane configurations. The power conversion stage includes internal filtering to mitigate line-side harmonics and transient noise, ensuring that firmware flash compatibility and deterministic communication speeds are maintained across the backplane bus during active operation.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is the F3PU10-0N module hot-swappable while the base unit is under load?\u003c\/p\u003e\n\u003cp\u003eA: No. The F3PU10-0N is not designed for hot-swapping. The AC input must be disconnected and the PLC base unit powered down before attempting to remove or install the power supply module.\u003c\/p\u003e\n\u003cp\u003eQ: Can the F3PU10-0N be used with backplanes larger than 6 slots?\u003c\/p\u003e\n\u003cp\u003eA: No. The F3PU10-0N is rated specifically for 4-slot or 6-slot configurations. Attempting to use this unit with higher-density backplanes may result in insufficient power capacity and system instability.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eVerify that the incoming AC supply is within the 100-240 VAC range before connection to prevent damage to the internal conversion circuitry.\u003c\/li\u003e\n\u003cli\u003eEnsure the module is seated fully into the power supply slot of the 4 or 6 slot base unit, and tighten the mounting screws to ensure proper grounding to the PLC chassis.\u003c\/li\u003e\n\u003cli\u003eKeep AC input cabling separated from sensitive low-voltage I\/O signal wiring to prevent electromagnetic induction.\u003c\/li\u003e\n\u003cli\u003eConfirm that the ventilation slots on the base unit are unobstructed to allow for adequate heat dissipation of the power supply and adjacent modules.\u003c\/li\u003e\n\u003cli\u003eCheck that the module's status LED indicates a nominal output state after power-up; if the LED remains unlit, verify the source voltage and confirm the module is securely latched.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49253217599740,"sku":"F3PU10-0N","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/F3PU10-0N.jpg?v=1783302016","url":"https:\/\/www.electronicplc.com\/ar\/products\/f3pu10-0n-power-supply-module-yokogawa","provider":"Electronic PLC","version":"1.0","type":"link"}