{"product_id":"f3pu10-0s-power-supply-module-yokogawa","title":"F3PU10-0S Power Supply Module Yokogawa","description":"\u003cp\u003eConfigured for power regulation in FA-M3 PLC networks, the \u003cstrong\u003eYokogawa F3PU10-0S\u003c\/strong\u003e (\u003cstrong\u003eF3PU10-0S\u003c\/strong\u003e Power Supply Module) provides direct electrical conversion and distribution to base units and connected I\/O components.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3PU10-0S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.34 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard FA-M3 Module Slot Format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e35 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 V AC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003e2.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eF3BU04-0N, F3BU06-0N Base Modules\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control and Power Isolation\u003c\/h3\u003e\n\u003cp\u003eThe module architecture integrates multi-stage galvanic isolation to protect the backplane bus from fluctuations in the input power line. By utilizing high-frequency switching regulation, the unit minimizes thermal dissipation while maintaining constant voltage output. The design ensures that channel-to-channel noise interference is suppressed, maintaining signal integrity for sensitive modules mounted on the same base unit. The input stage supports global standard AC ranges, accommodating diverse industrial power grids without the requirement for external transformers.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: What is the primary function of the F3PU10-0S in an FA-M3 system?\u003c\/p\u003e\n\u003cp\u003eA: The module serves as the primary DC voltage source, converting AC line power to a stabilized 5 VDC rail to drive the CPU and various I\/O modules mounted on the base unit.\u003c\/p\u003e\n\u003cp\u003eQ: Is this power supply unit capable of hot-swapping during system operation?\u003c\/p\u003e\n\u003cp\u003eA: No, this module is not designed for hot-swap operations. The system power must be disconnected at the main input terminals before removing or installing the module to prevent electrical arcing or potential damage to the backplane pins.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the main AC power source is isolated and locked out prior to physical handling of the module.\u003c\/li\u003e\n\u003cli\u003eAlign the module housing with the guide rails of the F3BU04-0N or F3BU06-0N base module.\u003c\/li\u003e\n\u003cli\u003eSlide the module into the designated slot until the locking mechanism engages securely with the base unit.\u003c\/li\u003e\n\u003cli\u003eConnect the input AC lines to the terminal block, ensuring proper torque according to local electrical codes to prevent connection heating.\u003c\/li\u003e\n\u003cli\u003eVerify that the PE (Protective Earth) terminal is connected to a low-impedance ground point to ensure effective EMI shielding and electrical safety.\u003c\/li\u003e\n\u003cli\u003eCheck for clearance around the module ventilation slots to maintain the rated operating temperature range.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49208238407932,"sku":"F3PU10-0S","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/F3PU10-0S1.jpg?v=1781761287","url":"https:\/\/www.electronicplc.com\/ar\/products\/f3pu10-0s-power-supply-module-yokogawa","provider":"Electronic PLC","version":"1.0","type":"link"}