{"product_id":"f3pu30-0s-yokogawa-power-supply-module-datasheet-manual","title":"F3PU30-0S Yokogawa Power Supply Module Datasheet \u0026 Manual","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa F3PU30-0S\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eF3PU30\u003c\/strong\u003e Power Supply Module, operates as a dedicated hardware component for power conditioning and distribution within the FA-M3 Range-free Multi-controller architecture.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3PU30-0S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.38 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e10.2 cm x 12.7 cm x 5.1 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Output Current\u003c\/td\u003e\n\u003ctd\u003e6.0 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e100-240 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eElectrical Performance and Protection\u003c\/h3\u003e\n\u003cp\u003eThe F3PU30-0S is engineered to maintain stable 5 V DC output regulation under fluctuating input conditions, supporting a range of 85-264 V AC. It provides an allowable momentary power failure time of 20 ms to ensure continuous logic execution during transient line disturbances. The module incorporates robust dielectric strength of 1500 V AC between external AC terminals and the frame ground (FG) terminal, alongside high insulation resistance of 5 MΩ. These characteristics ensure that the backplane bus communication velocity remains stable and protected from power-side noise, with a specified noise immunity level of 1500 Vp-p.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the F3PU30-0S module require external cooling fans?\u003c\/p\u003e\n\u003cp\u003eA: No, the module is designed for convective cooling. Ensure that vertical clearance of at least 10 cm is maintained above and below the module to allow for adequate heat dissipation.\u003c\/p\u003e\n\u003cp\u003eQ: How does the module handle a sustained input voltage drop below 85 V AC?\u003c\/p\u003e\n\u003cp\u003eA: The internal protection circuits will trigger a low-voltage shutdown to protect the downstream controller modules. The output will be disabled until the input voltage returns to the rated operating range.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eTerminal Wiring\u003c\/strong\u003e: Secure AC input leads and the frame ground (FG) wire to the terminal block. Ensure that the FG terminal is connected to the protective earth bus using a conductor with a minimum cross-section of 2 mm squared to maintain electrical safety.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting\u003c\/strong\u003e: Install the power supply in the leftmost slot of the FA-M3 base unit to minimize voltage drop across the backplane bus. Fasten all mounting screws securely to ensure a rigid electrical connection.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSeparation\u003c\/strong\u003e: Maintain a minimum distance of 15 cm from high-power electromagnetic sources or inductive loads to prevent noise injection into the power supply output.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePeriodic Inspection\u003c\/strong\u003e: Inspect the terminal connections annually for signs of thermal oxidation or loose fasteners. Verify the output voltage at the backplane monitoring point to ensure it remains within the nominal 5 V DC threshold.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49165204127996,"sku":"F3PU30-0S","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/F3PU30-0S1.jpg?v=1780624892","url":"https:\/\/www.electronicplc.com\/ar\/products\/f3pu30-0s-yokogawa-power-supply-module-datasheet-manual","provider":"Electronic PLC","version":"1.0","type":"link"}