{"product_id":"f3wd64-3f-digital-input-module-yokogawa","title":"F3WD64-3F Digital Input Module Yokogawa","description":"\u003cp\u003eConfigured for high-density signal acquisition in FA-M3 control networks, the \u003cstrong\u003eYokogawa F3WD64-3F\u003c\/strong\u003e (\u003cstrong\u003eF3WD64-3F\u003c\/strong\u003e Digital Input Module) provides direct physical\/electrical execution of 64-point discrete monitoring.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eF3WD64-3F\u003c\/strong\u003e: Base module designation for a 64-point digital input unit, engineered for high-speed process sensing within the FA-M3 modular controller platform.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3WD64-3F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003ejapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.15 kg (0.34 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Points\u003c\/td\u003e\n\u003ctd\u003e64 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 0.1 A per point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e40-pin connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Control and I\/O Density Scaling\u003c\/h3\u003e\n\u003cp\u003eThe F3WD64-3F module utilizes a high-density input architecture to maximize cabinet space utilization while maintaining deterministic communication with the FA-M3 backplane. The module is designed for reliable signal capture at the 24 VDC logic level, ensuring that input transitions are registered with high accuracy for sequence control tasks. By utilizing a 40-pin connector interface, the module facilitates efficient wiring for large-scale I\/O density scaling, ensuring that backplane bus communication velocity is not compromised by the high number of active input points.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the F3WD64-3F module support hot-swapping during active PLC operation?\u003c\/p\u003e\n\u003cp\u003eA: No. The F3WD64-3F is not designed for hot-swapping. The base unit power must be disconnected before attempting to install or remove the module to prevent electrical damage to the backplane communication pins.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module compatible with all FA-M3 series base racks?\u003c\/p\u003e\n\u003cp\u003eA: Compatibility is contingent on the specific backplane revision and power supply capacity; please confirm the physical slot requirements for the 40-pin connector configuration before system integration.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the module securely in the designated FA-M3 base unit slot, ensuring the connector pins are fully engaged with the backplane to prevent intermittent signal issues.\u003c\/li\u003e\n\u003cli\u003eVerify that the incoming 24 VDC field signal voltage is stable and within the module's operating parameters before energizing the input loops.\u003c\/li\u003e\n\u003cli\u003eUtilize a 40-pin mating cable assembly that matches the module pin-out configuration, ensuring all wire terminals are crimped and secured to prevent vibration-induced disconnections.\u003c\/li\u003e\n\u003cli\u003eSeparate the input signal cables from high-voltage AC lines to mitigate electromagnetic interference, which can cause phantom input transitions.\u003c\/li\u003e\n\u003cli\u003ePerform a diagnostic loop check using the PLC programming software after installation to verify that all 64 input points are correctly mapped and responsive to field signal states.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49253316198652,"sku":"F3WD64-3F","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/F3WD64-3F1.jpg?v=1783302016","url":"https:\/\/www.electronicplc.com\/ar\/products\/f3wd64-3f-digital-input-module-yokogawa","provider":"Electronic PLC","version":"1.0","type":"link"}