{"product_id":"f3xd64-3f-k2-yokogawa-digital-input-module","title":"F3XD64-3F\/K2 Yokogawa Digital Input Module","description":"\u003cp\u003eConfigured for high-density discrete signal acquisition in FA-M3 control networks, the \u003cstrong\u003eYokogawa F3XD64-3F\/K2\u003c\/strong\u003e (\u003cstrong\u003eF3XD64-3F\/K2\u003c\/strong\u003e Digital Input Module) provides direct electrical execution for 64-channel field device interfacing via the system backplane.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe F3XD64-3F\/K2 represents the high-density digital input configuration within the FA-M3 series. The suffix \"\/K2\" designates specific terminal block and interface compatibility standards, ensuring physical and electrical alignment with the standard FA-M3 modular rack systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3XD64-3F\/K2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.14 kg \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard FA-M3 single-slot form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e75 mA (5 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e64\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Input Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Response Time\u003c\/td\u003e\n\u003ctd\u003e0, 62.5, 250, 1000, 16000 us (Selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eYokogawa DCS and Process Control Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe F3XD64-3F\/K2 is engineered for seamless integration into Yokogawa DCS and PLC environments, providing essential signal conditioning for process control loops. The module architecture incorporates photocoupler-based channel-to-channel isolation to maintain signal integrity and suppress electrical noise when interfaced with remote field instrumentation. By adhering to standardized input voltage thresholds (16.0 V DC for ON state), the module ensures deterministic data acquisition across all 64 channels, suitable for high-speed process monitoring and sequence control.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this module support both sink and source input configurations?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The F3XD64-3F\/K2 is designed to accommodate both sink and source input wiring, allowing it to adapt to various field device signal polarities without hardware modification.\u003c\/p\u003e\n\u003cp\u003eQ: Is this module capable of hot-swapping?\u003c\/p\u003e\n\u003cp\u003eA: No. Standard FA-M3 modules are not designed for hot-swapping. The power to the rack must be removed before installing or removing the module to prevent electrical arcing or damage to the backplane communication pins.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the installation environment is free from conductive debris and excessive moisture to maintain the integrity of the input circuitry.\u003c\/li\u003e\n\u003cli\u003eAlign the 40-pin connector carefully during installation to prevent bent pins; ensure the locking mechanism is fully secured.\u003c\/li\u003e\n\u003cli\u003eUtilize shielded twisted pair cables for signal runs exceeding 3 meters to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eTerminate all cable shields to a dedicated, low-impedance earth ground at the control panel entry point.\u003c\/li\u003e\n\u003cli\u003eVerify that the common supply voltage for field sensors is verified as 24 V DC prior to final connection to the module terminals.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49243170799868,"sku":"F3XD64-3F\/K2","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/F3XD64-3FK21.jpg?v=1782956036","url":"https:\/\/www.electronicplc.com\/ar\/products\/f3xd64-3f-k2-yokogawa-digital-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}