{"product_id":"foxboro-i-a-series-fbm218-communication-module","title":"Foxboro FBM218 I\/A Series HART Communication Redundant Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Foxboro FBM218 (P0922VW) is a high-availability HART Communication Redundant Output Module designed for the I\/A Series Distributed Control System (DCS). This module provides eight isolated analog output channels, each capable of superimposed HART digital communication. It is specifically engineered for mission-critical applications in sectors such as oil refining, chemical processing, and power generation where continuous valve control and instrument diagnostics are paramount. The FBM218 supports redundant pair configurations, allowing two modules to operate in tandem to ensure that control output is maintained even in the event of a single module failure.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEight isolated 4-20 mA analog output channels with HART support.\u003c\/li\u003e\n\u003cli\u003eSupports 1-for-1 functional redundancy for high-availability control.\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation (600 VAC) between channels and from earth to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eHigh-speed digital-to-analog conversion with 13-bit resolution.\u003c\/li\u003e\n\u003cli\u003eSeamless integration with the 2 Mbps I\/A Series Fieldbus.\u003c\/li\u003e\n\u003cli\u003eProvides deep diagnostic insight into intelligent field actuators.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe FBM218 is intended for use in industrial environments requiring precise control and monitoring, including:\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eOil and gas refining processes.\u003c\/li\u003e\n\u003cli\u003eChemical and petrochemical manufacturing.\u003c\/li\u003e\n\u003cli\u003ePower generation facilities.\u003c\/li\u003e\n\u003cli\u003eCritical loop control where downtime must be minimized.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFBM218 (P0922VW)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Type\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC with HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.05% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e13 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e600 VAC (Channel-to-Earth\/Channel-to-Channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e7 Watts (Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system is powered down before inserting or removing the module from the baseplate.\u003c\/li\u003e\n\u003cli\u003eThe FBM218 must be installed in a compatible I\/A Series baseplate; for redundant configurations, ensure modules are placed in the designated adjacent slots.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for field connections to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding of the module chassis to the system common to ensure effective galvanic isolation.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eCompliance and Certifications\u003c\/h3\u003e\u003cp\u003eThe FBM218 is designed for use in hazardous locations and meets the following standards: CE, CSA, and FM Approved for Class 1 Division 2.\u003c\/p\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eDoes this module support HART communication?\u003c\/strong\u003e Yes, the FBM218 is specifically designed to support superimposed HART digital communication on all eight output channels.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eCan this module be used in a redundant configuration?\u003c\/strong\u003e Yes, the FBM218 supports 1-for-1 functional redundancy when installed in a redundant baseplate, allowing for seamless failover.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":50721249362172,"sku":"FBM218","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_b3b8efb3-f11f-4b79-9ee0-72bd9f3df4d8.jpg?v=1785149019","url":"https:\/\/www.electronicplc.com\/ar\/products\/foxboro-i-a-series-fbm218-communication-module","provider":"Electronic PLC","version":"1.0","type":"link"}