{"product_id":"foxboro-i-a-series-p0916ag-input-module","title":"Foxboro P0916AG I\/A Series HART Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Foxboro P0916AG is a high-performance HART Communication Input Interface Module designed for the I\/A Series (Intelligent Automation) system. Engineered for critical process automation in industries such as oil refining, chemical processing, and power generation, this Field Bus Module (FBM) provides eight individual input channels. It serves as a vital bridge between field devices and the control network, supporting 4-20 mA analog signals alongside digital HART data. By enabling real-time diagnostic monitoring and remote configuration of field instruments, the P0916AG significantly reduces plant downtime and optimizes maintenance cycles through predictive asset management.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEight galvanically isolated input channels for high signal integrity.\u003c\/li\u003e\n\u003cli\u003eSupports simultaneous 4-20 mA analog and HART digital communication.\u003c\/li\u003e\n\u003cli\u003eEnables bidirectional data exchange for secondary variables and device diagnostics.\u003c\/li\u003e\n\u003cli\u003eOptimized for high-density DIN rail mounting within the I\/A Series 200 system.\u003c\/li\u003e\n\u003cli\u003eSupports redundant configurations to ensure high system availability.\u003c\/li\u003e\n\u003cli\u003eReduces maintenance overhead via remote instrument configuration and predictive diagnostics.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is widely utilized in process control environments including oil and gas refineries, chemical manufacturing plants, and power generation facilities. It is ideal for applications requiring high-precision analog data acquisition combined with the advanced diagnostic capabilities of HART-enabled field instrumentation.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eFoxboro (Schneider Electric)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eP0916AG\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeries\u003c\/td\u003e\n\u003ctd\u003eI\/A Series 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eFBM214 HART Input Interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 Isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Signal\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC with HART\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 Ohms (nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.03% of span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e3.5 Watts (Maximum)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5 to 95% (Non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the control system is powered down before inserting or removing the module from the baseplate.\u003c\/li\u003e\n\u003cli\u003eMount the module in a clean, dry environment within the specified temperature range to prevent overheating.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for field inputs to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the module chassis to the system common to maintain galvanic isolation integrity.\u003c\/li\u003e\n\u003cli\u003eVerify that all field wiring is securely terminated and conforms to local electrical codes for Class 1 Division 2 hazardous locations if applicable.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the P0916AG?\u003c\/h3\u003e\u003cp\u003eThe P0916AG acts as an interface between field instruments and the Foxboro I\/A Series control system, allowing for the acquisition of 4-20 mA signals while simultaneously passing HART digital data for device diagnostics and configuration.\u003c\/p\u003e\u003ch3\u003eDoes this module support redundancy?\u003c\/h3\u003e\u003cp\u003eYes, the P0916AG is designed to support redundant configurations, which is critical for maintaining process continuity in high-availability automation applications.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":50730385604860,"sku":"P0916AG","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_ed739c53-0f6e-4428-b8c4-ba863c60485c.jpg?v=1785221482","url":"https:\/\/www.electronicplc.com\/ar\/products\/foxboro-i-a-series-p0916ag-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}