{"product_id":"ge-fanuc-quickpanel-qpi2d100l2p-human-machine-interface","title":"GE Fanuc QPI2D100L2P QuickPanel Human Machine Interface","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc QPI2D100L2P is a high-reliability industrial operator terminal engineered for machine-level control and data visualization. Programmed via QuickDesigner Version 3.7, this Human Machine Interface (HMI) coordinates data flows between operators and machine networks within continuous-process applications such as metal casting, mining extraction, and chemical processing. The robust construction provides a localized control hub that withstands the environmental stressors of heavy factory floors, minimizing process blindness and reducing operational downtime.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e10.4-inch monochrome LCD matrix display for clear data visualization.\u003c\/li\u003e\n\u003cli\u003ePassive, natural air convection cooling architecture to protect internal components from dust, oil mist, and particulates.\u003c\/li\u003e\n\u003cli\u003eIntegrated serial communication port (SI\/O) for multi-protocol PLC networking.\u003c\/li\u003e\n\u003cli\u003eDedicated download interface port for project updates and system maintenance.\u003c\/li\u003e\n\u003cli\u003e20-millisecond power dropout tolerance to safeguard active memory during voltage dips or phase shifts.\u003c\/li\u003e\n\u003cli\u003eNEMA 4X\/12 and IP65 rated enclosure for harsh industrial environments.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis HMI is designed for demanding industrial environments, including metal casting, mining, chemical processing, and general manufacturing lines where localized control and immediate fault diagnostics are required.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQPI2D100L2P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eGE Fanuc Total Control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Family\u003c\/td\u003e\n\u003ctd\u003eQuickPanel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e10.4-inch Monochrome LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC (20.4 to 27.6 VDC range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e50 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDropout Immunity\u003c\/td\u003e\n\u003ctd\u003e20 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003ctd\u003eQuickDesigner Version 3.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 50 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-10 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003e30 to 85 percent (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eNEMA 4X\/12, IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the unit is mounted in a panel cutout that meets the specified dimensions to maintain the NEMA\/IP seal integrity.\u003c\/li\u003e\n\u003cli\u003eUse shielded communication cables for serial connections to minimize EMI interference from high-voltage equipment.\u003c\/li\u003e\n\u003cli\u003eVerify that the power supply is stable and within the 20.4 to 27.6 VDC range before applying power.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate clearance around the unit to allow for natural air convection cooling.\u003c\/li\u003e\n\u003cli\u003eEnsure the unit is properly grounded to the cabinet chassis to prevent electrical noise and potential damage from static discharge.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat software is required to program the QPI2D100L2P?\u003c\/h3\u003e\u003cp\u003eThis unit requires QuickDesigner Version 3.7 for project development and system configuration.\u003c\/p\u003e\u003ch3\u003eDoes this unit support color graphics?\u003c\/h3\u003e\u003cp\u003eNo, the QPI2D100L2P features a monochrome LCD matrix display.\u003c\/p\u003e\u003ch3\u003eWhat is the power requirement for this HMI?\u003c\/h3\u003e\u003cp\u003eThe unit operates on 24 VDC, with an acceptable operating window of 20.4 to 27.6 VDC.\u003c\/p\u003e","brand":"GE FANUC","offers":[{"title":"Default Title","offer_id":50953227796732,"sku":"QPI2D100L2P","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_9a05d27e-24d5-4ffd-9c3f-c9f451e582ff.jpg?v=1786236885","url":"https:\/\/www.electronicplc.com\/ar\/products\/ge-fanuc-quickpanel-qpi2d100l2p-human-machine-interface","provider":"Electronic PLC","version":"1.0","type":"link"}