{"product_id":"ge-fanuc-series-90-70-ic697pwr710-power-supply-module","title":"General Electric IC697PWR710 Series 90-70 PLC Power Supply Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe IC697PWR710 is a high-performance power supply module designed for the General Electric Series 90-70 programmable logic controller (PLC) platform. This rack-mountable unit provides regulated +5 VDC power and essential logic-level sequencing signals to the system backplane. Engineered for versatility, it supports a wide range of input voltages, including 120\/240 VAC or 125 VDC, making it suitable for diverse industrial environments. The module features active power factor correction and integrated protection against overcurrent and overvoltage conditions to ensure system stability.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOperates on 120\/240 VAC (90-264 VAC range) or 125 VDC (100-150 VDC range).\u003c\/li\u003e\n\u003cli\u003eDelivers up to 56 watts of output power with a nominal 5.1 VDC output.\u003c\/li\u003e\n\u003cli\u003eSupports up to 11 amps of current on the 5V bus.\u003c\/li\u003e\n\u003cli\u003eActive power factor correction (PF \u0026gt; 0.95) for efficient energy usage.\u003c\/li\u003e\n\u003cli\u003eCapable of powering two racks simultaneously, provided the total load is within the 56W rating.\u003c\/li\u003e\n\u003cli\u003eIntegrated electronic short-circuit and overcurrent protection.\u003c\/li\u003e\n\u003cli\u003eSlide-in rack mount design for installation in the leftmost slot of a Series 90-70 rack.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eProcess manufacturing (chemical, pharmaceutical, and batch processing).\u003c\/li\u003e\n\u003cli\u003eTurbine control and monitoring systems.\u003c\/li\u003e\n\u003cli\u003eAutomated material handling and conveyor systems.\u003c\/li\u003e\n\u003cli\u003eHigh-precision metalworking and industrial assembly equipment.\u003c\/li\u003e\n\u003cli\u003eElectrical distribution and utility monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC697PWR710\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage (AC)\u003c\/td\u003e\n\u003ctd\u003e90 to 264 VAC, 47 to 63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage (DC)\u003c\/td\u003e\n\u003ctd\u003e100 to 150 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Power\u003c\/td\u003e\n\u003ctd\u003e56 Watts (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e4.90 to 5.25 VDC (5.1 VDC nominal)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Current\u003c\/td\u003e\n\u003ctd\u003eUp to 11 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRide Through Time\u003c\/td\u003e\n\u003ctd\u003e21 ms minimum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Factor\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 0.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOvervoltage Limit\u003c\/td\u003e\n\u003ctd\u003e6.2 Volts\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eThe module must be installed in the leftmost slot of the Series 90-70 rack, which is dedicated to the power supply.\u003c\/li\u003e\n\u003cli\u003eEnsure the system power is disconnected before inserting or removing the module from the backplane.\u003c\/li\u003e\n\u003cli\u003eUse copper AWG #16 (1.3mm2) wire rated for 75 degC for power input connections (L1 and N).\u003c\/li\u003e\n\u003cli\u003eThe ground terminal must be connected to the rack GND terminal and earth using copper AWG #12 (3.3mm2) wire rated for 75 degC to ensure proper grounding.\u003c\/li\u003e\n\u003cli\u003eVerify that all wiring is secure and that the same wire type\/size is used for terminals.\u003c\/li\u003e\n\u003cli\u003eMaintain adequate ventilation around the rack to prevent overheating.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the IC697PWR710?\u003c\/h3\u003e\u003cp\u003eThe IC697PWR710 is a 56-Watt power supply module for the GE Series 90-70 PLC system, providing 5V DC power and sequencing signals to the rack.\u003c\/p\u003e\u003ch3\u003eCan this power supply support two racks?\u003c\/h3\u003e\u003cp\u003eYes, a single IC697PWR710 can power two racks, provided the total power consumption of all modules in both racks does not exceed the 56-watt output capacity.\u003c\/p\u003e\u003ch3\u003eWhat protection features are included?\u003c\/h3\u003e\u003cp\u003eThe module includes electronic short-circuit protection on the 5V bus and overvoltage protection with a 6.2V limit.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50766875754748,"sku":"IC697PWR710","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_de95fa39-85d7-4cbd-a0cb-a166930ab02e.jpg?v=1785486687","url":"https:\/\/www.electronicplc.com\/ar\/products\/ge-fanuc-series-90-70-ic697pwr710-power-supply-module","provider":"Electronic PLC","version":"1.0","type":"link"}