{"product_id":"honeywell-8c-taima1-series-8-analog-input-module","title":"Honeywell 8C-TAIMA1 51307171-175 Low Level Analog Temperature Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Honeywell 8C-TAIMA1 (51307171-175) is a low-level analog input IOTA module designed for the Experion LX distributed control system. This module is engineered for high-precision temperature measurement, supporting both Thermocouple (TC) and Resistance Temperature Detector (RTD) inputs. It provides reliable signal processing for industrial temperature monitoring applications, featuring remote cold junction compensation and configurable Open Thermocouple Detection (OTD) protection.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eSupports both TC and RTD sensor types for versatile temperature monitoring.\u003c\/li\u003e\n\u003cli\u003eRemote Cold Junction compensation capability for improved measurement accuracy.\u003c\/li\u003e\n\u003cli\u003eConfigurable Open Thermocouple Detection (OTD) protection.\u003c\/li\u003e\n\u003cli\u003eSecond PV scanning functionality.\u003c\/li\u003e\n\u003cli\u003eScalable temperature point configuration in 16-point increments.\u003c\/li\u003e\n\u003cli\u003eHigh Common Mode Rejection Ratio (CMRR) of 120 dB at 50\/60 Hz.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is specifically designed for integration into Honeywell Experion LX systems, primarily used in process industries requiring precise temperature tracking, such as chemical processing, power generation, and refining operations where TC and RTD sensors are deployed for critical process control.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003e8C-TAIMA1 (51307171-175)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Current Rating\u003c\/td\u003e\n\u003ctd\u003e120 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel Bandwidth\u003c\/td\u003e\n\u003ctd\u003e0 to 4.7 Hz (-3 dB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTC Nominal Input Range\u003c\/td\u003e\n\u003ctd\u003e-20 to +100 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGain Error (-20 to +100 mV)\u003c\/td\u003e\n\u003ctd\u003e0.050% full scale max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance (TC)\u003c\/td\u003e\n\u003ctd\u003eMegohm at DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCMRR (50\/60 Hz)\u003c\/td\u003e\n\u003ctd\u003e120 dB min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Channel Isolation\u003c\/td\u003e\n\u003ctd\u003e+\/-33 VDC or VAC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannel-to-Shield Isolation\u003c\/td\u003e\n\u003ctd\u003e+\/-250 VDC or VAC RMS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the IOTA module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eMount the module in a clean, dry environment within the specified temperature range to ensure longevity.\u003c\/li\u003e\n\u003cli\u003eUse shielded cabling for all analog input signals to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the module shield terminals to the system common ground to maintain the integrity of low-level signals.\u003c\/li\u003e\n\u003cli\u003eVerify that the input wiring matches the configuration for TC or RTD sensors to prevent measurement errors or hardware damage.\u003c\/li\u003e\n\u003cli\u003eHandle with standard ESD precautions to protect sensitive internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat type of sensors does the 8C-TAIMA1 support?\u003c\/h3\u003e\u003cp\u003eThis module supports both Thermocouple (TC) and Resistance Temperature Detector (RTD) sensors, making it suitable for a wide range of industrial temperature sensing applications.\u003c\/p\u003e\u003ch3\u003eWhat is the primary function of the OTD protection?\u003c\/h3\u003e\u003cp\u003eThe Open Thermocouple Detection (OTD) protection is a configurable feature that identifies if a thermocouple circuit has been broken, allowing the control system to react appropriately to a loss of signal.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":50647231987964,"sku":"8C-TAIMA1","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_384cc4c5-c46b-4218-a907-b0e777ddd381.jpg?v=1785054109","url":"https:\/\/www.electronicplc.com\/ar\/products\/honeywell-8c-taima1-series-8-analog-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}