{"product_id":"honeywell-mu-taih02-high-level-analog-input-processor","title":"Honeywell MU-TAIH02 High Level Analog Input Processor","description":"\u003cp\u003eThe Honeywell MU-TAIH02 is a robust high-level analog input processor engineered for integration into industrial process control environments. This module facilitates the acquisition of signals from a variety of field instrumentation, including voltage and current sources, as well as 2-wire and self-powered transmitters. Featuring 16 differential input channels, it is specifically designed to maintain signal integrity in electrically demanding settings such as power generation facilities, chemical processing plants, and refinery automation systems.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 differential analog input channels with high common mode rejection.\u003c\/li\u003e\n\u003cli\u003eIntegrated 16-bit A\/D conversion architecture for precise measurement.\u003c\/li\u003e\n\u003cli\u003eSupports multiple signal ranges: 0-5V, 1-5V, 0.4-2V, and 4-20mA (via 250 Ohm conversion).\u003c\/li\u003e\n\u003cli\u003eIncludes single-pole RC filtering (-3 dB at 1 Hz) to mitigate normal mode interference.\u003c\/li\u003e\n\u003cli\u003eHigh input impedance (\u0026gt;10 MOhm) ensures minimal loading on field sensors.\u003c\/li\u003e\n\u003cli\u003eInternal protection circuitry allows for +\/- 30V differential input tolerance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThe MU-TAIH02 is widely utilized in Distributed Control Systems (DCS) for continuous process monitoring. Its high-accuracy sampling makes it suitable for turbine monitoring, mining automation, and general industrial instrumentation where stable, low-noise signal processing is required to prevent process instability.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMU-TAIH02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e16 Differential\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges\u003c\/td\u003e\n\u003ctd\u003e0-5V, 1-5V, 0.4-2V, 4-20mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16-bit (14-bit utilized)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Rate\u003c\/td\u003e\n\u003ctd\u003e4 samples\/second\/channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCMRR\u003c\/td\u003e\n\u003ctd\u003e70 dB (DC to 60 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNMRR\u003c\/td\u003e\n\u003ctd\u003e32 dB at 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (23.5 degC)\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.075% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (0-50 degC)\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.15% Full Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is completely disconnected before attempting to install or remove the module from the rack or chassis.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for all analog input signals to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eMaintain proper grounding practices for the cable shields at the designated grounding point to ensure effective noise rejection.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is fully seated in the chassis backplane connector to ensure reliable communication and power distribution.\u003c\/li\u003e\n\u003cli\u003eAvoid routing signal cables in close proximity to high-voltage power lines or high-frequency switching equipment.\u003c\/li\u003e\n\u003cli\u003eEnsure adequate ventilation around the rack to maintain operating temperatures within the specified range.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eWhat is the primary function of the MU-TAIH02?\u003c\/strong\u003e The MU-TAIH02 acts as a high-level analog input processor that converts various field signals into digital data for use within a Honeywell process control system.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eDoes this module support 4-20mA signals?\u003c\/strong\u003e Yes, the module supports 4-20mA signals through the use of an integrated 250 Ohm resistance conversion.\u003c\/p\u003e\u003cp\u003e\u003cstrong\u003eWhat is the sampling speed of this module?\u003c\/strong\u003e The module provides a scan rate of 4 samples per second per channel, with all 16 channels sampled within a 250 ms window.\u003c\/p\u003e","brand":"Honeywell","offers":[{"title":"Default Title","offer_id":51217362780412,"sku":"MU-TAIH02","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_929a5742-9528-4ca9-8267-e7ca1a378fc4.jpg?v=1788368604","url":"https:\/\/www.electronicplc.com\/ar\/products\/honeywell-mu-taih02-high-level-analog-input-processor","provider":"Electronic PLC","version":"1.0","type":"link"}