{"product_id":"ic200alg430-ge-fanuc-versamax-analog-combination-module","title":"General Electric IC200ALG430 VersaMax Analog Mixed Module","description":"\u003cp\u003eThe General Electric IC200ALG430 is a high-density 6-point analog combination module belonging to the VersaMax I\/O series. This module provides integrated signal processing capabilities, featuring four differential current inputs and two single-ended current outputs. It is engineered for precision control in various industrial environments, utilizing 12-bit resolution for both input and output channels to ensure reliable data conversion.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFour differential 4-20 mA current inputs in a single group.\u003c\/li\u003e\n\u003cli\u003eTwo single-ended 4-20 mA current outputs in a single group.\u003c\/li\u003e\n\u003cli\u003eHigh-resolution 12-bit analog-to-digital and digital-to-analog conversion.\u003c\/li\u003e\n\u003cli\u003eCompact VersaMax form factor for efficient rack space utilization.\u003c\/li\u003e\n\u003cli\u003eJumper-selectable output behavior for fault states (hold last state or default).\u003c\/li\u003e\n\u003cli\u003eIntegrated status LEDs for Field Power (FLD PWR) and Module OK monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eProcess Control:\u003c\/strong\u003e Ideal for managing flow, pressure, and valve positioning in petrochemical and chemical processing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater Management:\u003c\/strong\u003e Used for pump control, level monitoring, and chemical dosing systems.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Generation:\u003c\/strong\u003e Monitors critical generation parameters and manages field instrumentation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eManufacturing:\u003c\/strong\u003e Supports precise speed and flow regulation in automated production lines.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC200ALG430\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInputs\u003c\/td\u003e\n\u003ctd\u003e4 Differential (4-20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e2 Single-ended (4-20 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e12-bit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current\u003c\/td\u003e\n\u003ctd\u003e50mA max at 5VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Range\u003c\/td\u003e\n\u003ctd\u003e+18 to +30VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFilter Response\u003c\/td\u003e\n\u003ctd\u003e5.0ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e0.3ms (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500VAC for 1 minute (optical)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC backplane power is disconnected before installing or removing the module from the carrier.\u003c\/li\u003e\n\u003cli\u003eThe module requires an external 24VDC power supply to drive the output and field-side circuits.\u003c\/li\u003e\n\u003cli\u003eVerify that the jumper settings on the carrier are correctly configured for the desired output fault behavior (Hold Last State vs. Default).\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for analog signals to minimize electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eMaintain proper module ventilation to operate within the specified temperature range.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD (Electrostatic Discharge) precautions during handling to protect internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat signals does the IC200ALG430 support?\u003c\/h3\u003e\u003cp\u003eThis module is specifically designed for 4-20 mA current loops. It does not support voltage input\/output signals; please refer to the IC200ALG431 or IC200ALG432 for voltage-based applications.\u003c\/p\u003e\u003ch3\u003eHow does the module behave during a communication loss?\u003c\/h3\u003e\u003cp\u003eThe module's behavior is determined by the carrier jumper configuration. It can be set to either hold the last known output state or revert to a default state when backplane communication or power is interrupted.\u003c\/p\u003e\u003ch3\u003eIs external power mandatory for this module?\u003c\/h3\u003e\u003cp\u003eYes, an external 18-30VDC power source is required to operate the output channels and field-side instrumentation.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51214983725308,"sku":"IC200ALG430","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_058ffab4-8fd1-4e07-8e41-43ae312baf9f.jpg?v=1788285464","url":"https:\/\/www.electronicplc.com\/ar\/products\/ic200alg430-ge-fanuc-versamax-analog-combination-module","provider":"Electronic PLC","version":"1.0","type":"link"}