{"product_id":"ic670mdl740-ge-fanuc-field-control-discrete-output-module","title":"General Electric IC670MDL740 Field Control 16-Point Discrete Output Module","description":"\u003cp\u003eThe General Electric IC670MDL740 is a 16-point discrete output module, engineered as part of the Field Control I\/O series. This module provides 16 positive logic (sourcing) output channels, designed to interface with 24VDC control systems. It is optimized for distributed I\/O applications, offering a compact footprint and reliable switching for industrial automation tasks.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16-point positive logic output configuration.\u003c\/li\u003e\n\u003cli\u003eOperating voltage range: 10-30 VDC (24 VDC nominal).\u003c\/li\u003e\n\u003cli\u003eMaximum load current capacity of 0.5 Amps per point.\u003c\/li\u003e\n\u003cli\u003eIntegrated status LED indicators for individual output channel monitoring.\u003c\/li\u003e\n\u003cli\u003eBus Interface Unit (BIU) compatible for modular expansion.\u003c\/li\u003e\n\u003cli\u003eDIN-rail mountable design for efficient cabinet space utilization.\u003c\/li\u003e\n\u003cli\u003eIntegrated 25-terminal block supporting AWG #14 to #22 wire gauges.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eActuator and solenoid valve control in fluid or pneumatic systems.\u003c\/li\u003e\n\u003cli\u003eDriving interposing relay coils for high-power load switching.\u003c\/li\u003e\n\u003cli\u003ePowering pilot lamps and visual status indicators on control panels.\u003c\/li\u003e\n\u003cli\u003eIntegration into distributed I\/O architectures for machine and process automation.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC670MDL740\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Type\u003c\/td\u003e\n\u003ctd\u003eDiscrete (Positive Logic)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Points\u003c\/td\u003e\n\u003ctd\u003e16\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Range\u003c\/td\u003e\n\u003ctd\u003e10-30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent per Point\u003c\/td\u003e\n\u003ctd\u003e0.5 A Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Module Current\u003c\/td\u003e\n\u003ctd\u003e4.0 A Max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Draw (from BIU)\u003c\/td\u003e\n\u003ctd\u003e111 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e200 microseconds (at 0.5 A resistive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 VAC (1 min) \/ 250 VAC (continuous)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Protection\u003c\/td\u003e\n\u003ctd\u003e5 A, 250 V (5x20mm) slow-acting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the system power is disconnected before installing or removing the module from the DIN-rail.\u003c\/li\u003e\n\u003cli\u003eVerify that the BIU power supply matches the 111 mA current draw requirement.\u003c\/li\u003e\n\u003cli\u003eUse appropriate wire gauges (AWG #14-22); ensure terminal screws are tightened to secure connections.\u003c\/li\u003e\n\u003cli\u003eMaintain proper clearance for ventilation to prevent overheating in dense rack configurations.\u003c\/li\u003e\n\u003cli\u003eFollow standard ESD (Electrostatic Discharge) mitigation practices when handling the module circuitry.\u003c\/li\u003e\n\u003cli\u003eConfirm the positive logic configuration matches your field device requirements before energizing.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eIs the IC670MDL740 still supported?\u003c\/h3\u003e\u003cp\u003eWhile this unit may be designated as End-of-Life (EOL) by the manufacturer, it remains a functional component in many legacy GE Field Control systems. We continue to provide access to these modules for maintenance and system support.\u003c\/p\u003e\u003ch3\u003eCan I use this module for AC loads?\u003c\/h3\u003e\u003cp\u003eNo, the IC670MDL740 is specifically a DC output module (10-30 VDC). For applications requiring AC load switching, consider the IC670MDL930 relay module.\u003c\/p\u003e\u003ch3\u003eWhat should I do if my load exceeds 0.5A?\u003c\/h3\u003e\u003cp\u003eIf your specific application requires higher current, please refer to the IC670MDL742 (1.0A per point) or the IC670MDL730 (2.0A per point) modules for compatibility.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":51215624274172,"sku":"IC670MDL740","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_8d64bbb4-d90f-46b9-a296-506bf3aa3708.jpg?v=1788304734","url":"https:\/\/www.electronicplc.com\/ar\/products\/ic670mdl740-ge-fanuc-field-control-discrete-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}