{"product_id":"ic693alg223-ge-fanuc-series-90-30-analog-current-input-module","title":"General Electric IC693ALG223 16-Channel Analog Current Input Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe GE IC693ALG223 is a 16-channel analog current input module designed for the Series 90-30 PLC platform. This module serves as an interface between field instruments and the PLC, converting analog current signals into digital values for processing. It supports 16 single-ended input channels, each independently configurable for 0–20 mA, 4–20 mA, or 4–20 mA Enhanced input ranges. It is widely utilized in process control, manufacturing, water treatment, and power generation applications.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16-channel single-ended analog current inputs\u003c\/li\u003e\n\u003cli\u003eConfigurable input ranges: 0–20 mA, 4–20 mA, and 4–20 mA Enhanced\u003c\/li\u003e\n\u003cli\u003e1500 VAC field-to-logic isolation for surge protection\u003c\/li\u003e\n\u003cli\u003eIntegrated 200 Hz low-pass input filtering\u003c\/li\u003e\n\u003cli\u003eLED indicators for module status and external power monitoring\u003c\/li\u003e\n\u003cli\u003eCompatible with Series 90-30 5-slot and 10-slot baseplates\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eOil and gas: Monitoring pressure and temperature signals from pipelines\u003c\/li\u003e\n\u003cli\u003eWater treatment: Monitoring water pressure and dissolved oxygen levels\u003c\/li\u003e\n\u003cli\u003eNew energy: Collection of environmental parameters for wind and solar systems\u003c\/li\u003e\n\u003cli\u003eBuilding automation: Centralized sensor signal collection in HVAC systems\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Model\u003c\/td\u003e\n\u003ctd\u003eIC693ALG223\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e16 (Single-ended)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges\u003c\/td\u003e\n\u003ctd\u003e0-20 mA, 4-20 mA, 4-20 mA Enhanced\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (4-20 mA)\u003c\/td\u003e\n\u003ctd\u003e4 microamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution (0-20 mA)\u003c\/td\u003e\n\u003ctd\u003e5 microamps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e250 ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Rate\u003c\/td\u003e\n\u003ctd\u003e13 ms (all channels)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Filter Response\u003c\/td\u003e\n\u003ctd\u003e200 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC system is powered down before inserting or removing the module from the baseplate.\u003c\/li\u003e\n\u003cli\u003eThe module occupies a single slot in any Series 90-30 5-slot or 10-slot baseplate.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for analog signals to minimize EMI\/RFI interference.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the cable shields at the field instrument or the panel entry point.\u003c\/li\u003e\n\u003cli\u003eVerify that the 24 VDC external power supply is correctly connected to the module terminals.\u003c\/li\u003e\n\u003cli\u003eHandle with care using ESD-safe practices to prevent damage to internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the difference between the IC693ALG223 and IC693ALG222?\u003c\/h3\u003e\u003cp\u003eThe IC693ALG223 is designed specifically for current inputs (mA), whereas the IC693ALG222 is designed for voltage inputs (VDC).\u003c\/p\u003e\u003ch3\u003eWhat is the required external power for this module?\u003c\/h3\u003e\u003cp\u003eThe module requires 120 mA from the +5 VDC backplane and 65 mA from a 24 VDC external user supply.\u003c\/p\u003e\u003ch3\u003eHow many modules can be installed in a system?\u003c\/h3\u003e\u003cp\u003eThe number of modules depends on the specific CPU model; for instance, Model 311\/313\/323 supports up to 4 modules, while larger systems like 351\/352 support up to 51 modules.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50740466680060,"sku":"IC693ALG223","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_5fe9d4bd-bb48-428c-9e68-dc2042775d1d.jpg?v=1785408628","url":"https:\/\/www.electronicplc.com\/ar\/products\/ic693alg223-ge-fanuc-series-90-30-analog-current-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}