{"product_id":"ic693mdl940-ge-fanuc-series-90-30-relay-output-module","title":"General Electric IC693MDL940 90-30 Series 16-Point Relay Output Module","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe General Electric IC693MDL940 is a 16-point relay output module designed for the Series 90-30 Programmable Logic Controller (PLC) system. This module provides 16 normally-open (N.O.) relay circuits, allowing for the control of a wide range of user-supplied AC or DC load devices. It is an essential component for interfacing the PLC with field devices such as motor starters, solenoids, and indicators.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e16 normally-open relay outputs arranged in four groups of four points each.\u003c\/li\u003e\n\u003cli\u003eOutput switching capacity of 2 Amps per point.\u003c\/li\u003e\n\u003cli\u003eSupports a wide range of operating voltages: 5 to 30 VDC and 5 to 250 VAC (50\/60 Hz).\u003c\/li\u003e\n\u003cli\u003eLED status indicators for each of the 16 points, located on the front panel for easy diagnostics.\u003c\/li\u003e\n\u003cli\u003eColor-coded red left edge on the door insert to signify a high-voltage module.\u003c\/li\u003e\n\u003cli\u003eCompatible with any I\/O slot in a 5 or 10-slot baseplate within the Series 90-30 system.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eInjection Molding Machines:\u003c\/strong\u003e Robot I\/O and auxiliary control for systems like Cincinnati Milacron Roboshot.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMaterial Handling:\u003c\/strong\u003e Activation of starters and solenoids for conveyors, sorters, and palletizers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePackaging Machinery:\u003c\/strong\u003e Triggering actuators for bottling and wrapping processes.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWater \u0026amp; Wastewater:\u003c\/strong\u003e Operation of gate valves and pumps.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHVAC Systems:\u003c\/strong\u003e Management of fans, dampers, and heaters.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eIC693MDL940\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutputs\u003c\/td\u003e\n\u003ctd\u003e16 (4 groups of 4)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current (per output)\u003c\/td\u003e\n\u003ctd\u003e2 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current (per common)\u003c\/td\u003e\n\u003ctd\u003e4 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e5-30 VDC \/ 5-250 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500V (field to logic), 500V (group to group)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e15 ms max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMin Load\u003c\/td\u003e\n\u003ctd\u003e10 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInrush Current\u003c\/td\u003e\n\u003ctd\u003e5 Amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePower Down:\u003c\/strong\u003e Always disconnect power from the PLC baseplate before inserting or removing the module.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSlot Compatibility:\u003c\/strong\u003e This module can be installed in any I\/O slot of a 5 or 10-slot baseplate.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Field devices must be powered by an external user-supplied source. Ensure proper grouping to maintain isolation between different voltage types.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHandling:\u003c\/strong\u003e Use standard ESD precautions when handling the module to prevent damage to internal logic components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIdentification:\u003c\/strong\u003e Use the hinged door insert to record circuit identification information for easier maintenance.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQs\u003c\/h3\u003e\u003ch3\u003eWhat is the GE IC693MDL940?\u003c\/h3\u003e\u003cp\u003eThe GE Fanuc IC693MDL940 is a 16-point, 2-amp normally-open relay output module for the Series 90-30 PLC family.\u003c\/p\u003e\u003ch3\u003eHow are the output points organized?\u003c\/h3\u003e\u003cp\u003eThe 16 relay outputs are divided into 4 independent groups, with 4 channels per group. Each group shares a common power terminal.\u003c\/p\u003e\u003ch3\u003eCan I mix different voltages on the same module?\u003c\/h3\u003e\u003cp\u003eYes, you may use different voltage types on the same module, provided that they are kept in separate isolated groups.\u003c\/p\u003e\u003ch3\u003eDoes this module include internal fuses?\u003c\/h3\u003e\u003cp\u003eNo, there are no internal fuses on the IC693MDL940 module. External fusing is recommended based on the specific load requirements.\u003c\/p\u003e","brand":"General Electric","offers":[{"title":"Default Title","offer_id":50646861545724,"sku":"IC693MDL940","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_f2323ba8-8935-4ad2-a031-64d798bca134.jpg?v=1785047204","url":"https:\/\/www.electronicplc.com\/ar\/products\/ic693mdl940-ge-fanuc-series-90-30-relay-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}