{"product_id":"nfai143-h50-a4as0-analog-input-module-yokogawa","title":"NFAI143-H50\/A4AS0 Analog Input Module Yokogawa","description":"\u003cp\u003eConfigured for high-density signal acquisition within DCS architectures, the \u003cstrong\u003eYokogawa NFAI143-H50\/A4AS0\u003c\/strong\u003e (\u003cstrong\u003eNFAI143-H50\/A4AS0\u003c\/strong\u003e Analog Input Module) provides direct physical and electrical execution of 16-channel analog signal processing.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eNFAI143-H50\/A4AS0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.3 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard DIN-rail mount form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e230 mA at 5 V DC, 540 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 isolated channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Range\u003c\/td\u003e\n\u003ctd\u003e4-20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Update Cycle\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.1% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWithstanding Voltage\u003c\/td\u003e\n\u003ctd\u003e1500 V AC (input to system)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Loop Performance\u003c\/h3\u003e\n\u003cp\u003eThe NFAI143-H50\/A4AS0 incorporates galvanic isolation to decouple field-side loops from the internal system bus, minimizing the propagation of common-mode noise and ground loops. This architecture supports 4-20 mA HART loop protocol integration, allowing for simultaneous analog process variable monitoring and digital diagnostic data transmission. The input circuitry is engineered to maintain signal integrity through precise cold junction compensation mechanisms where applicable, while providing overcurrent protection to isolate channel faults from the main control processor backplane.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the module support hot-swapping under power?\u003c\/p\u003e\n\u003cp\u003eA: The NFAI143-H50\/A4AS0 is designed for modular insertion; however, system-level safety protocols dictate that the I\/O rack backplane power should be de-energized or the specific slot disabled in the DCS configuration before physical removal to prevent backplane bus communication transients.\u003c\/p\u003e\n\u003cp\u003eQ: How is the 1500 V AC withstanding voltage rating maintained during installation?\u003c\/p\u003e\n\u003cp\u003eA: The isolation integrity is maintained through internal galvanic barriers. Users must ensure that no physical bridging or conductive path is created between the field terminal wiring and the system-side backplane connectors during cabinet wiring.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the mounting rack is free of conductive debris before sliding the module into the designated slot.\u003c\/li\u003e\n\u003cli\u003eVerify that field wiring conforms to 4-20 mA loop standards, ensuring that loop shields are grounded at a single point, preferably at the cabinet entry, to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003eUtilize appropriate ferrules for wire termination to the terminal block to maintain a secure electrical connection and prevent strand fraying.\u003c\/li\u003e\n\u003cli\u003eConfirm that the input current does not exceed the maximum allowable 24 mA to prevent activation of the internal overcurrent protection circuitry.\u003c\/li\u003e\n\u003cli\u003eAfter seating the module, secure the front-face retaining screws to ensure proper electrical contact with the chassis ground and to provide mechanical stability against vibration.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49245922033916,"sku":"NFAI143-H50\/A4AS0","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/NFAI143-H50A4AS0.jpg?v=1783043694","url":"https:\/\/www.electronicplc.com\/ar\/products\/nfai143-h50-a4as0-analog-input-module-yokogawa","provider":"Electronic PLC","version":"1.0","type":"link"}