{"product_id":"nfbu050-s10-short-base-module-yokogawa","title":"NFBU050-S10 Short Base Module YOKOGAWA","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYOKOGAWA NFBU050-S10\u003c\/strong\u003e, also cataloged as the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNFBU050\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eShort Base Module, operates as a dedicated hardware component for field control network mounting within FCN-RTU system platforms. This module provides the mechanical and electrical backplane interface required to host I\/O modules in space-constrained industrial control cabinets.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe NFBU050-S10 signifies a specific base unit configuration optimized for Yokogawa FCN-RTU architectures. The \"S10\" suffix designates the standard short-form base design, which accommodates a limited number of module slots compared to full-length base plates, facilitating high-density installation in standardized 19-inch racks or localized enclosures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eNFBU050-S10\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYOKOGAWA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJAPAN\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eWeight\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e1.5 kg\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eDimensions\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e130 mm x 142.5 mm x 65.8 mm\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Temp\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e-20 deg C to 70 deg C\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003ePower Consumption\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e20 W max\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eAltitude\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eUp to 3000 m\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eDIN rail or 19-inch rack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eFOUNDATION Fieldbus Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe NFBU050-S10 utilizes internal backplane bus protocols to support module communication within the FCN-RTU architecture. It facilitates seamless signal distribution for modules supporting 4-20 mA HART loop protocol connectivity, ensuring that field data is transmitted with low latency to the CPU. The mechanical design enforces channel-to-channel isolation through strategic board layout, preventing signal crosstalk during high-speed data acquisition cycles.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Is this base module compatible with hot-swap operations for connected I\/O modules?\u003c\/p\u003e\n\u003cp\u003eA: The NFBU050-S10 supports the removal and insertion of compatible I\/O modules under power, provided the FCN-RTU system configuration allows for hot-swapping in the current state. Ensure all latching mechanisms are fully engaged to maintain backplane contact integrity.\u003c\/p\u003e\n\u003cp\u003eQ: Can the base module be mounted directly in high-vibration areas?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the module is constructed for mounting on standard DIN rails or 19-inch racks. For high-vibration environments, verify that the DIN rail clips are locked and that the base is secured to the enclosure backplane at all designated mounting points to mitigate mechanical fatigue.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eVerify the mounting surface is flat and free of debris. If installing on a DIN rail, ensure the rail is securely fastened to the cabinet chassis to provide an adequate ground reference.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAlign the base module with the mounting rail and press firmly until the locking mechanism clicks into place.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWhen installing modules into the base, ensure alignment with the backplane connectors. Apply even pressure to the module faceplate until it is flush with the base.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTighten all retention screws on the module faceplates to ensure optimal mechanical stability and electrical grounding to the base chassis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfirm that the power supply to the base unit is within the specified range before engaging the system. Check for proper bus voltage levels across the backplane terminals.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49257682862332,"sku":"NFBU050-S10","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/NFBU050-S10.jpg?v=1783388621","url":"https:\/\/www.electronicplc.com\/ar\/products\/nfbu050-s10-short-base-module-yokogawa","provider":"Electronic PLC","version":"1.0","type":"link"}