{"product_id":"pw482-10-yokogawa-power-supply-module-new-original-stock","title":"PW482-10 YOKOGAWA Power Supply Module New \u0026 Original Stock","description":"\u003cp\u003eConfigured for power conversion in DCS process control platforms, the \u003cstrong\u003eYOKOGAWA PW482-10\u003c\/strong\u003e (\u003cstrong\u003ePW482-10\u003c\/strong\u003e Power Supply Module) provides direct physical\/electrical execution.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003ePW482-10\u003c\/strong\u003e: High-power variant; provides dual output voltage rails of +12 VDC and +24 VDC with a maximum total power capacity of 480 W.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePW482-10 S2\u003c\/strong\u003e: Low-power variant; provides a single 24 VDC output rail configuration.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd data-row=\"1\"\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"2\"\u003eModel\u003c\/td\u003e\n\u003ctd data-row=\"2\"\u003ePW482-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"3\"\u003eBrand\u003c\/td\u003e\n\u003ctd data-row=\"3\"\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"4\"\u003eOrigin\u003c\/td\u003e\n\u003ctd data-row=\"4\"\u003eSubject to factory batch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"5\"\u003eWeight\u003c\/td\u003e\n\u003ctd data-row=\"5\"\u003e0.9 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"6\"\u003eDimensions\u003c\/td\u003e\n\u003ctd data-row=\"6\"\u003e5.1 cm x 20.3 cm x 15.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"7\"\u003eOperating Temp\u003c\/td\u003e\n\u003ctd data-row=\"7\"\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"8\"\u003ePower Consumption\u003c\/td\u003e\n\u003ctd data-row=\"8\"\u003e480 W (Max output)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"9\"\u003eInput Voltage\u003c\/td\u003e\n\u003ctd data-row=\"9\"\u003e100-120 VAC \/ 220-240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"10\"\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd data-row=\"10\"\u003e+12 VDC \/ +24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd data-row=\"11\"\u003eOutput Current\u003c\/td\u003e\n\u003ctd data-row=\"11\"\u003e40 A at 12 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eProcess Control Power Stabilization\u003c\/h3\u003e\n\u003cp\u003eThe module employs specialized circuitry for channel-to-channel isolation and voltage regulation required in DCS instrumentation loops. To maintain the requisite output stability, the power supply utilizes internal feedback loops to compensate for variations in line voltage. The +12 VDC and +24 VDC rails are designed for low ripple characteristics, facilitating stable operation for sensitive analog input and output modules within the YOKOGAWA architecture. Proper thermal management is required, as the unit operates across an extended range of -20 deg C to +70 deg C, necessitating adequate cabinet ventilation to prevent internal component fatigue.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the PW482-10 be utilized in environments with high electromagnetic interference?\u003c\/p\u003e\n\u003cp\u003eA: Yes, provided that proper shielded cabling and a low-impedance ground path are established to maintain the integrity of the output voltage rails against external transient interference.\u003c\/p\u003e\n\u003cp\u003eQ: Is the +12 VDC and +24 VDC output combination fixed, or can it be adjusted?\u003c\/p\u003e\n\u003cp\u003eA: The voltage rails are fixed output values determined by the internal regulator configuration. There are no user-adjustable potentiometers for output voltage modification on this module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the module in a well-ventilated enclosure, ensuring that the heatsink fins are oriented vertically to permit natural convection airflow.\u003c\/li\u003e\n\u003cli\u003ePrior to wiring, verify that the AC input voltage configuration matches the site supply (100-120 VAC or 220-240 VAC) to prevent input stage damage.\u003c\/li\u003e\n\u003cli\u003eEnsure that all output DC conductors are sized appropriately for the 40 A maximum current load to minimize voltage drops and thermal buildup at terminal interfaces.\u003c\/li\u003e\n\u003cli\u003eAll grounding lugs must be securely fastened to the common cabinet chassis ground using star washers to ensure electrical continuity for safety and noise suppression.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49134294860028,"sku":"PW482-10","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/PW482-10.jpg?v=1779760807","url":"https:\/\/www.electronicplc.com\/ar\/products\/pw482-10-yokogawa-power-supply-module-new-original-stock","provider":"Electronic PLC","version":"1.0","type":"link"}