{"product_id":"s9344fa-yokogawa-connector-module-new-original-stock","title":"S9344FA YOKOGAWA Connector Module | New \u0026 Original Stock","description":"\u003cp\u003eConfigured for signal routing within FA-M3 automation system architectures, the \u003cstrong\u003eYOKOGAWA S9344FA\u003c\/strong\u003e (\u003cstrong\u003eS9344FA\u003c\/strong\u003e Connector Interface) provides direct physical signal transition and bus connectivity. This hardware component serves as the modular interface bridge utilized to execute deterministic data exchange and communication across industrial automation platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eS9344FA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eSubject to factory marking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e150 mm x 120 mm x 30 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 W maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eDIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eStandard industrial protocols\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSystem Integration and Data Communication\u003c\/h3\u003e\n\u003cp\u003eThe S9344FA facilitates high-speed data transfer required for complex manufacturing and process control tasks. Within the FA-M3 architecture, the module acts as a passive or active routing point, depending on the specific backplane configuration. It supports standard industrial communication protocols, ensuring that the latency between the controller and peripheral field devices remains within required timing constraints for real-time applications.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Can the S9344FA module be hot-swapped while the FA-M3 system is under load?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed for modular detachment; however, hot-swapping capability is dependent on the specific base unit and CPU configuration of the FA-M3 system. Always verify the system manual before performing extraction while energized to avoid potential bus communication errors.\u003c\/p\u003e\n\u003cp\u003eQ: Is the 24 VDC power supply isolated from the communication signal pins?\u003c\/p\u003e\n\u003cp\u003eA: The internal design incorporates signal-to-power isolation to prevent transient voltage spikes on the power rail from corrupting data signals. Ensure that the external 24 VDC source is regulated to prevent fluctuations that could trigger an over-voltage protection state.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eDIN Rail Mounting:\u003c\/strong\u003e Mount the S9344FA securely on a standard DIN rail. Ensure the locking latch is fully engaged to prevent mechanical vibration from loosening the module, which could cause intermittent signal loss on the communication bus.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Management:\u003c\/strong\u003e Use shielded cables for all interface connections. Route these cables through dedicated conduits to minimize electromagnetic interference (EMI) originating from high-voltage motors or VFDs within the same control cabinet.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Considerations:\u003c\/strong\u003e While rated for -20 deg C to +60 deg C, maintain adequate spacing (minimum 20 mm) between the S9344FA and other high-heat modules in the rack to ensure efficient thermal dissipation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eConnector Integrity:\u003c\/strong\u003e Inspect the connector pins periodically for signs of oxidation or deformation. Use a contact cleaner if necessary, but ensure the system is de-energized to prevent accidental short circuits across the interface pins.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49181384966396,"sku":"S9344FA","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/ADR541-P00.jpg?v=1781143674","url":"https:\/\/www.electronicplc.com\/ar\/products\/s9344fa-yokogawa-connector-module-new-original-stock","provider":"Electronic PLC","version":"1.0","type":"link"}