{"product_id":"schneider-electric-modicon-momentum-171ccc96030-processor-adapter","title":"Schneider Electric 171CCC96030 Modicon Momentum M1E Processor Adapter","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe 171CCC96030 is a high-efficiency M1E processor adapter designed for the Schneider Electric Modicon Momentum distributed automation architecture. This module integrates seamlessly with standard I\/O bases to execute control logic and manage data routing. By leveraging the Transparent Ready framework, it provides direct Ethernet TCP\/IP connectivity, enabling efficient data acquisition and network synchronization in demanding industrial environments such as power generation, oil and gas, and mining.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eIntegrated 10\/100 Mbps Ethernet port for Modbus TCP\/IP and HTTP web server access.\u003c\/li\u003e\n\u003cli\u003eOnboard web server for remote diagnostics and system monitoring.\u003c\/li\u003e\n\u003cli\u003eSupports up to 4 simultaneous TCP connections for HMI, programming, and peer-to-peer communication.\u003c\/li\u003e\n\u003cli\u003eDedicated RS485 serial port for Modbus RTU\/ASCII master or slave connectivity.\u003c\/li\u003e\n\u003cli\u003eComprehensive LED diagnostic array for real-time status monitoring (RUN, ERR, LAN ST, I\/O).\u003c\/li\u003e\n\u003cli\u003eCompact design for direct mounting onto Modicon Momentum I\/O bases.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis processor adapter is engineered for distributed control applications where high-speed communication and local processing are required. It is commonly deployed in remote terminal units (RTUs), automated process control systems, and distributed I\/O architectures requiring seamless integration with Ethernet-based plant networks.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e171CCC96030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessor Type\u003c\/td\u003e\n\u003ctd\u003eProprietary RISC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUser Application Memory\u003c\/td\u003e\n\u003ctd\u003e180 kB RAM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45 (10\/100 Base-TX)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003e1 x RS485 (Modbus RTU\/ASCII)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e2.5 W at 5 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95% (non-condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection Grade\u003c\/td\u003e\n\u003ctd\u003eIP20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure power is disconnected from the I\/O base before installing or removing the processor adapter.\u003c\/li\u003e\n\u003cli\u003eAlign the internal board-to-board connector carefully with the I\/O base to prevent pin damage.\u003c\/li\u003e\n\u003cli\u003eMaintain proper ventilation around the module to ensure the operating temperature remains within the 0 to 60 deg C range.\u003c\/li\u003e\n\u003cli\u003eUse shielded twisted-pair cabling for Ethernet connections to minimize EMI interference in industrial environments.\u003c\/li\u003e\n\u003cli\u003eVerify that the module is securely latched to the I\/O base to ensure reliable backplane communication.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat is the primary function of the 171CCC96030?\u003c\/h3\u003e\u003cp\u003eIt acts as a processor adapter that mounts onto a Modicon Momentum I\/O base, providing control logic execution and Ethernet connectivity for the distributed I\/O system.\u003c\/p\u003e\u003ch3\u003eDoes this module require an external power supply?\u003c\/h3\u003e\u003cp\u003eNo, the module is powered directly via the internal bus from the connected Modicon Momentum I\/O base.\u003c\/p\u003e\u003ch3\u003eWhat protocols are supported by the Ethernet port?\u003c\/h3\u003e\u003cp\u003eThe Ethernet port supports Modbus TCP\/IP, HTTP for web server access, as well as BOOTP and DHCP for network configuration.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50910075027708,"sku":"171CCC96030","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_bd6d90e0-f2fc-46a3-8f18-e11af0606d61.jpg?v=1785641893","url":"https:\/\/www.electronicplc.com\/ar\/products\/schneider-electric-modicon-momentum-171ccc96030-processor-adapter","provider":"Electronic PLC","version":"1.0","type":"link"}