{"product_id":"schneider-tsxdey32d2k-discrete-input-module","title":"Schneider TSXDEY32D2K Modicon Premium Discrete Input Module","description":"\u003cp\u003eThe Schneider TSXDEY32D2K is a high-density discrete input module designed for the Modicon Premium PLC platform. It provides 32 isolated current sink inputs, specifically engineered to interface with 2- or 3-wire proximity sensors in demanding industrial automation environments. This module offers reliable signal processing with robust electrical isolation and fast response times.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e32 isolated discrete input channels.\u003c\/li\u003e\n\u003cli\u003eCompatible with standard 24 V DC positive logic.\u003c\/li\u003e\n\u003cli\u003eDesigned for integration with 2- or 3-wire proximity sensors.\u003c\/li\u003e\n\u003cli\u003eHigh input impedance for signal integrity.\u003c\/li\u003e\n\u003cli\u003eStandard HE-10 connector interface for efficient wiring.\u003c\/li\u003e\n\u003cli\u003eLow power dissipation design suitable for high-density rack configurations.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cp\u003eThis module is typically utilized in manufacturing and process control systems where high-density digital signal acquisition is required, such as conveyor control, assembly line monitoring, and machine safety interlocks within the Modicon Premium ecosystem.\u003c\/p\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003eTSXDEY32D2K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePlatform\u003c\/td\u003e\n\u003ctd\u003eModicon Premium PLC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e32 isolated current sink\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC positive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor Power Supply\u003c\/td\u003e\n\u003ctd\u003e19 to 30 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current\u003c\/td\u003e\n\u003ctd\u003e3.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Impedance\u003c\/td\u003e\n\u003ctd\u003e6300 Ohm at state 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Threshold (State 1)\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 11 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Threshold (State 0)\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 5 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;= 7 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrical Isolation\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 10 MOhm at 500 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Dissipation\u003c\/td\u003e\n\u003ctd\u003e1 W + 0.1 W per active channel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e135 mA at 5 V DC \/ 160 mA at 24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eHE-10 connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 degC to +60 degC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eEnsure the PLC rack is powered down before inserting or removing the module to prevent electrical damage.\u003c\/li\u003e\n\u003cli\u003eUse shielded cables for input signals to minimize electromagnetic interference (EMI) in high-noise industrial environments.\u003c\/li\u003e\n\u003cli\u003eVerify that the sensor power supply is within the 19–30 V DC range before connecting field devices.\u003c\/li\u003e\n\u003cli\u003eEnsure proper grounding of the Modicon Premium rack to maintain electrical isolation integrity.\u003c\/li\u003e\n\u003cli\u003eHandle the module by the housing to avoid electrostatic discharge (ESD) damage to the internal circuitry.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat type of sensors can be used with the TSXDEY32D2K?\u003c\/h3\u003e\u003cp\u003eThis module is designed for use with 2- or 3-wire proximity sensors operating on 24 V DC positive logic.\u003c\/p\u003e\u003ch3\u003eWhat is the connection interface for this module?\u003c\/h3\u003e\u003cp\u003eThe module utilizes a standard HE-10 connector for field wiring, which facilitates quick and reliable connections to terminal blocks or distribution boards.\u003c\/p\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":50975075270908,"sku":"TSXDEY32D2K","price":172.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_640c50a7-c902-43c1-b350-7f2e412741a8.jpg?v=1786640909","url":"https:\/\/www.electronicplc.com\/ar\/products\/schneider-tsxdey32d2k-discrete-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}