{"product_id":"siemens-6es7336-4ge00-0ab0-simatic-s7-failsafe-analog-input-module","title":"Siemens 6ES7336-4GE00-0AB0 SIMATIC S7-300 Fail-Safe Analog Input Module SM 336","description":"\u003ch3\u003eDescription\u003c\/h3\u003e\u003cp\u003eThe Siemens 6ES7336-4GE00-0AB0 SIMATIC S7-300 SM 336 is a high-performance, fail-safe analog input module designed for safety-critical process automation. As part of the SIMATIC S7-300 and ET 200M distributed I\/O systems, this module provides reliable signal acquisition for applications requiring high functional safety, including SIL 3 (IEC 61508) compliance. It features six analog input channels specifically designed for 0\/4–20 mA current signals, supporting both 2-wire and 4-wire transmitter configurations.\u003c\/p\u003e\u003ch3\u003eFeatures\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eFail-safe analog inputs for safety-instrumented systems (SIS).\u003c\/li\u003e\n\u003cli\u003e6 isolated analog input channels.\u003c\/li\u003e\n\u003cli\u003e15-bit resolution plus sign (up to 16-bit with overrange).\u003c\/li\u003e\n\u003cli\u003eNative HART protocol support for bidirectional communication, remote configuration, and diagnostics.\u003c\/li\u003e\n\u003cli\u003eReverse polarity protection for the 24V DC supply.\u003c\/li\u003e\n\u003cli\u003eSupports SIL 3, Category 4, and PL e safety standards.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eApplications\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003eChemical and petrochemical plants for reactor pressure and temperature monitoring.\u003c\/li\u003e\n\u003cli\u003eOil and gas refinery safety systems.\u003c\/li\u003e\n\u003cli\u003ePower plant burner management and steam control systems.\u003c\/li\u003e\n\u003cli\u003eIndustrial safety monitoring in automotive paint shops and hazardous zones.\u003c\/li\u003e\n\u003cli\u003eAutomated logistics and crane load monitoring.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\u003ctable border=\"1\"\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e6ES7336-4GE00-0AB0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Inputs\u003c\/td\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA, 4 to 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e15-bit + sign (16-bit max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e150 Ohm (typ), 175 Ohm (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRated Supply Voltage\u003c\/td\u003e\n\u003ctd\u003e24 V DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption (L+)\u003c\/td\u003e\n\u003ctd\u003e150 mA (typ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption (Bus)\u003c\/td\u003e\n\u003ctd\u003e90 mA (max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Loss\u003c\/td\u003e\n\u003ctd\u003e4.5 W (typ)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e370V AC for 1 minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Cable Length\u003c\/td\u003e\n\u003ctd\u003e1000 meters (shielded)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\u003ch3\u003eInstallation Guidelines\u003c\/h3\u003e\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting:\u003c\/strong\u003e Hook the module onto the S7-300 DIN rail and swing it into place. Secure it using the integrated mounting screw.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eBus Connection:\u003c\/strong\u003e Ensure the U-shaped bus connector is securely seated in the backplane to establish communication with the CPU or adjacent modules.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring:\u003c\/strong\u003e Use a 20-pin front connector for field wiring. Always use shielded cables for analog signals to minimize EMI interference.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding:\u003c\/strong\u003e Utilize a shielding bracket to ground cable shields as close to the module as possible.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSafety:\u003c\/strong\u003e Ensure power is disconnected before installing or removing the module from the rack.\u003c\/li\u003e\n\u003c\/ul\u003e\u003ch3\u003eFAQ\u003c\/h3\u003e\u003ch3\u003eWhat safety levels does this module support?\u003c\/h3\u003e\u003cp\u003eIt is designed for SIMATIC Safety and supports up to SIL 3 (IEC 61508), Category 4 (EN 954-1), and PL e (ISO 13849).\u003c\/p\u003e\u003ch3\u003eWhich CPUs is this module compatible with?\u003c\/h3\u003e\u003cp\u003eIt can be used in the S7-300 central rack or as remote I\/O in the ET 200M chassis, allowing connectivity with S7-300, S7-400, S7-1200, and S7-1500 series controllers.\u003c\/p\u003e\u003ch3\u003eCan it be used for standard applications?\u003c\/h3\u003e\u003cp\u003eYes, the module can be configured for standard analog input tasks or as a fail-safe module for SIL 2\/3 safety applications.\u003c\/p\u003e","brand":"Siemens","offers":[{"title":"Default Title","offer_id":50645529166076,"sku":"6ES7336-4GE00-0AB0","price":80.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/wm_1_de89e4fc-fa60-4230-804b-3dd7c1fa81b6.jpg?v=1784979670","url":"https:\/\/www.electronicplc.com\/ar\/products\/siemens-6es7336-4ge00-0ab0-simatic-s7-failsafe-analog-input-module","provider":"Electronic PLC","version":"1.0","type":"link"}