{"product_id":"signal-cable-yokogawa-akb331-m030","title":"Signal Cable Yokogawa AKB331-M030","description":"\u003cp\u003eConfigured for high-density signal interconnects between I\/O modules and terminal boards within DCS and SIS network platforms, the \u003cstrong\u003eYokogawa AKB331-M030\u003c\/strong\u003e (\u003cstrong\u003eAKB331\u003c\/strong\u003e Signal Cable) provides direct physical and electrical execution of multi-pin circuit connectivity.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eAKB331\u003c\/strong\u003e: Specifies the base hardware series for 50-pin to 50-pin signal cable assemblies designed for Yokogawa SDV\/SAT module interfacing.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eM030\u003c\/strong\u003e: Denotes a fixed cable length of 30 meters.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAKB331-M030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e30 m length\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot applicable (Passive component)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e50-pin to 50-pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\u003c\/td\u003e\n\u003ctd\u003eSDV144, SDV531, SDV53A, SDV541, SAT145\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Connectivity and Signal Integrity\u003c\/h3\u003e\n\u003cp\u003eThe AKB331-M030 utilizes specialized shielding configurations designed to maintain signal integrity during long-distance transmission between field termination assemblies and the DCS I\/O backplane. The cable design facilitates 4-20 mA HART loop protocol compatibility by maintaining controlled impedance across the 50-pin interface. The implementation of channel-to-channel isolation within the connected termination assembly, supported by this cable's wire density, prevents signal crosstalk and electromagnetic interference in high-density control cabinets.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the AKB331-M030 cable be shortened or spliced in the field?\u003c\/p\u003e\n\u003cp\u003eA: Field splicing of the AKB331-M030 is not recommended. Altering the cable length or connector geometry will compromise the impedance characteristics and shielding continuity, potentially introducing signal latency or communication errors in the connected I\/O loops.\u003c\/p\u003e\n\u003cp\u003eQ: Are there specific grounding requirements for the cable shield?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The cable shield must be terminated at a verified instrument earth point on the cabinet chassis to ensure effective EMI suppression. Ensure the cable drain wire is secured to the designated grounding lug to maintain proper shielding potential.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eCable Routing: Route signal cables through dedicated metallic cable trays separated from high-voltage AC lines and VFD output cabling to minimize inductive noise coupling into the 50-pin signal path.\u003c\/li\u003e\n\u003cli\u003eBend Radius: Maintain a minimum bending radius of at least 10 times the cable diameter to prevent mechanical stress on the internal conductor array or degradation of the outer PVC jacket.\u003c\/li\u003e\n\u003cli\u003eConnector Engagement: Verify that the 50-pin connectors are fully seated and that the integrated locking clips are fully engaged. Ensure no mechanical tension is applied to the connector pins, as excessive strain can lead to intermittent contact failure in critical SIS applications.\u003c\/li\u003e\n\u003cli\u003eEnvironmental Protection: In hazardous or harsh industrial areas, ensure the cable is installed within conduit systems if mechanical protection or chemical resistance beyond the factory-rated jacket is required.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49265635590396,"sku":"AKB331-M030","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AKB331-M030.jpg?v=1783647838","url":"https:\/\/www.electronicplc.com\/ar\/products\/signal-cable-yokogawa-akb331-m030","provider":"Electronic PLC","version":"1.0","type":"link"}