{"product_id":"ssc60d-s2512-yokogawa-safety-control-unit","title":"SSC60D-S2512 Yokogawa Safety Control Unit","description":"\u003cp\u003eThe \u003cstrong\u003eYokogawa SSC60D-S2512\u003c\/strong\u003e is a high-performance Safety Control Unit (SCU) specifically engineered for the ProSafe-RS Safety Instrumented System (SIS). It serves as the primary processing engine for safety-critical logic in industrial automation, providing high-availability control for emergency shutdown (ESD) and fire and gas (F\u0026amp;G) applications.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eSSC60D-S2512\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eSafety Control Unit (SCU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 to 40 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100-120 V AC (Dual-Redundant)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003eISA Standard G3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExplosion Protection\u003c\/td\u003e\n\u003ctd\u003eNone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eIndustrial Safety and Operational Integrity\u003c\/h3\u003e\n\u003cp\u003eThe SSC60D utilizes the Vnet\/IP control network architecture to ensure deterministic, high-speed communication within the SIS. The dual-redundant power supply configuration minimizes the risk of single-point failure, maintaining the required Safety Integrity Level (SIL) for hazardous processes. By operating within the ISA G3 environmental standard, the unit provides robust protection against corrosive atmospheric conditions, ensuring long-term hardware reliability in demanding industrial plants such as refineries and chemical manufacturing facilities.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What does the \"Without Safety Control Function License\" suffix indicate?\u003c\/p\u003e\n\u003cp\u003eA: This suffix confirms the unit is supplied without a pre-installed R4.01+ software license. Licensing must be procured and applied according to the specific safety logic requirements of your installation project.\u003c\/p\u003e\n\u003cp\u003eQ: Is this unit compatible with previous versions of ProSafe-RS?\u003c\/p\u003e\n\u003cp\u003eA: The SSC60D series is designed for integration with ProSafe-RS environments. However, firmware compatibility is strictly version-dependent; verify that your existing system engineering station supports the SSC60D hardware revision before deployment.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eMechanical Installation\u003c\/strong\u003e: The unit is rack-mountable; ensure the structure is rated to support the 8.5 kg mass. Install in a cabinet with adequate vertical spacing to allow for the thermal management required by high-density safety controllers.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eElectrical Grounding\u003c\/strong\u003e: Connect the frame ground to a low-impedance safety instrumented ground bus. High-quality grounding is mandatory to prevent electromagnetic interference (EMI) from affecting the sub-millisecond scan times of the safety processor.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eNetwork Connectivity\u003c\/strong\u003e: Utilize the Vnet\/IP interface with shielded category 6 cabling. Ensure that network traffic is segmented as per Yokogawa’s recommended SIS network topology to maintain deterministic packet delivery.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Management\u003c\/strong\u003e: While the unit is G3 compliant, it is highly sensitive to rapid temperature fluctuations. Ensure the control room or cabinet utilizes climate control to maintain the -20 to 40 °C ambient range, which maximizes the service life of internal electronic components.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49165306200316,"sku":"SSC60D-F2542","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/SSC60D-F25421.jpg?v=1780624895","url":"https:\/\/www.electronicplc.com\/ar\/products\/ssc60d-s2512-yokogawa-safety-control-unit","provider":"Electronic PLC","version":"1.0","type":"link"}