{"product_id":"ycb301-c100-l-5м-yokogawa-esb-bus-cable-new-original-stock","title":"YCB301-C100 L=5м YOKOGAWA ESB Bus Cable | New \u0026 Original Stock","description":"\u003cp\u003eConfigured for communication synchronization in CENTUM VP control systems, the \u003cstrong\u003eYOKOGAWA YCB301-C100\u003c\/strong\u003e (\u003cstrong\u003eYCB301\u003c\/strong\u003e ESB Bus Cable) provides direct physical and electrical execution of ESB bus signal transport between Field Control Units and node units.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe YCB301 series utilizes a specific suffix code structure to define cable length requirements for system interconnects:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eModel YCB301:\u003c\/strong\u003e 36-pin to 36-pin ESB bus interconnect cable.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSuffix C100:\u003c\/strong\u003e Specifies a standard cable length of 1 meter.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eYCB301-C100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.4 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 x 1.8 x 13.2 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive (Signal transmission)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Rating\u003c\/td\u003e\n\u003ctd\u003e60 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Rating\u003c\/td\u003e\n\u003ctd\u003e0.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003e36-pin Solder terminals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Connectivity and Loop Integrity\u003c\/h3\u003e\n\u003cp\u003eThe YCB301-C100 cable assembly employs a multi-conductor architecture designed for high-density signal throughput. Each conductor is engineered to support AWG #20 to #24 wire sizes, ensuring low resistance and consistent signal propagation across the ESB Bus network. The cable architecture facilitates channel-to-channel isolation, reducing the risk of induced crosstalk in dense cabinet environments. By maintaining precise impedance characteristics, the cable supports the deterministic timing required for field control unit data exchange. When deployed within the CENTUM VP architecture, the assembly serves as the primary transmission medium, ensuring that 32-channel signal capacity is maintained without attenuation or data packet loss.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the YCB301-C100 support high-speed data transmission for all node types?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The cable is designed for standard ESB Bus data rates used in CENTUM VP systems, supporting reliable signal transport between FCUs and node units.\u003c\/p\u003e\n\u003cp\u003eQ: Can this cable be trimmed or modified for specific cabinet lengths?\u003c\/p\u003e\n\u003cp\u003eA: The cable is provided as a factory-terminated assembly with 36-pin connectors. Modifying the length or replacing connectors is not recommended as it compromises the factory-certified impedance and shielding integrity.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eRoute the YCB301-C100 through cable management trays separated from high-voltage AC cabling to prevent electromagnetic induction.\u003c\/li\u003e\n\u003cli\u003eObserve the specified bend radius during installation; excessive tension or sharp bending can damage the internal conductors and connector solder joints.\u003c\/li\u003e\n\u003cli\u003eAlign the 36-pin connectors with the module interface slots, ensuring the latching mechanisms are fully engaged to provide secure physical contact.\u003c\/li\u003e\n\u003cli\u003eVerify pin-to-pin continuity before system startup to ensure no internal wiring faults occurred during cable routing.\u003c\/li\u003e\n\u003cli\u003eSecure the cable with strain relief clips at both ends to prevent physical stress on the backplane connectors due to the weight of the assembly.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49199374008572,"sku":"YCB301-C100 L=5м","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/ESB_YCB301-C100.jpg?v=1781229269","url":"https:\/\/www.electronicplc.com\/ar\/products\/ycb301-c100-l-5%d0%bc-yokogawa-esb-bus-cable-new-original-stock","provider":"Electronic PLC","version":"1.0","type":"link"}