{"product_id":"yokogawa-aip830-001-eim-operation-keyboard","title":"Yokogawa AIP830-001\/EIM Operation Keyboard","description":"\u003cp\u003eConfigured for human-machine interface (HMI) interaction in process control environments, the \u003cstrong\u003eYokogawa AIP830-001\/EIM\u003c\/strong\u003e (\u003cstrong\u003eAIP830-001\u003c\/strong\u003e Operation Keyboard) provides direct physical input execution for system monitoring and operator command sequences.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eSuffix Code\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAIP830-001\u003c\/td\u003e\n\u003ctd\u003eBase operation keyboard model\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\/EIM\u003c\/td\u003e\n\u003ctd\u003eEnhanced interface and module integration variant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAIP830-001\/EIM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard HMI console footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e5 deg C to 40 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V (+\/- 5%) via USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Current\u003c\/td\u003e\n\u003ctd\u003e1 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eUSB 2.0 (Bus-powered)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHMI Interaction and USB Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe AIP830-001\/EIM serves as a dedicated tactile interface for DCS and SCADA console operators. The unit utilizes a USB 2.0 full-speed interface, drawing power directly from the host computer’s bus to minimize external cabling requirements. In addition to standard command inputs, the keyboard integrates a USB 1.1 compliant sound function, enabling local audio feedback for process alarms and system events. The chassis is finished in a Munsell No. N1.5 equivalent black coating, designed to reduce glare and optimize ergonomics within high-intensity control room environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the keyboard be connected to a USB hub?\u003c\/p\u003e\n\u003cp\u003eA: The AIP830-001\/EIM requires a stable 1 A power draw. It is recommended to connect the unit directly to the workstation's dedicated USB port to ensure sufficient power delivery and minimize potential bus-powered latency or connection drops.\u003c\/p\u003e\n\u003cp\u003eQ: Are specific drivers required for the sound function?\u003c\/p\u003e\n\u003cp\u003eA: The device utilizes standard USB HID and audio class drivers. Most modern industrial operating systems will recognize the interface automatically; however, ensure the HMI software is configured to route system alerts to the keyboard's audio output if local notification is required.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003ePosition the keyboard on a flat, vibration-dampened surface to ensure operator comfort and device stability during high-frequency input tasks.\u003c\/li\u003e\n\u003cli\u003eRoute the USB cable away from sources of high-frequency electromagnetic interference (EMI), such as power converters or heavy motor controllers, to prevent data communication interrupts.\u003c\/li\u003e\n\u003cli\u003eEnsure the workstation USB port is securely fixed; frequent mechanical strain on the port can lead to intermittent power delivery or connection loss, which may trigger system-wide HMI communication alarms.\u003c\/li\u003e\n\u003cli\u003eMaintain the operating environment between 5 deg C and 40 deg C; exceeding this range may impact the tactile response of the keys and the long-term reliability of the internal audio circuitry.\u003c\/li\u003e\n\u003cli\u003eIf the keyboard is used in an environment with high dust or moisture content, utilize a console cover to protect the key switches from ingress.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49227509694716,"sku":"AIP830-001\/EIM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AIP830-101EIM.jpg?v=1781487121","url":"https:\/\/www.electronicplc.com\/ar\/products\/yokogawa-aip830-001-eim-operation-keyboard","provider":"Electronic PLC","version":"1.0","type":"link"}