{"product_id":"yokogawa-aip831-101-eim-operation-keyboard","title":"YOKOGAWA AIP831-101\/EIM Operation Keyboard","description":"\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA AIP831-101\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003eAIP831-101\u003c\/strong\u003e Operation Keyboard, operates as a dedicated hardware component for simultaneous multi-loop process control within CENTUM VP Human Interface System platforms.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAIP831-101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.0 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard desktop form factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e5 deg C to 40 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e1 A (Max)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e5 VDC +\/- 5% (via USB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003e2 x USB A type (USB 2.0\/1.1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChassis Color\u003c\/td\u003e\n\u003ctd\u003eBlack (Munsell No. N1.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHART Loop and DCS Connectivity Protocols\u003c\/h3\u003e\n\u003cp\u003eThe AIP831-101 integrates directly with the CENTUM VP environment to facilitate streamlined process control via specialized touch sensor arrays. The device maintains signal integrity by utilizing a dedicated USB 2.0 interface for operational commands and a secondary USB 1.1 channel for auditory alarm feedback. To ensure robust performance within the DCS environment, the keyboard supports instrument faceplate highlighting functions, requiring consistent 5 VDC power delivery via the host USB port to maintain sub-millisecond response latency during operator-to-system interaction.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the touch sensor interface support operation while the user is wearing protective industrial gloves?\u003c\/p\u003e\n\u003cp\u003eA: No, the touch sensor technology utilized in the AIP831-101 is calibrated exclusively for tactile detection by bare hands.\u003c\/p\u003e\n\u003cp\u003eQ: Is the USB speaker assembly capable of being driven by external audio sources outside of the CENTUM VP alarm system?\u003c\/p\u003e\n\u003cp\u003eA: The sound function is hardware-restricted to alarm buzzer notifications generated by the connected Human Interface System to prevent audio signal interference with process alerts.\u003c\/p\u003e\n\u003cp\u003eQ: Can the keyboard be powered by an external power supply instead of the host USB port?\u003c\/p\u003e\n\u003cp\u003eA: No, the device is designed to draw power exclusively from the host USB port; exceeding the specified 5 VDC +\/- 5% range may result in internal controller failure.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Positioning\u003c\/strong\u003e: Ensure the installation surface is leveled and the ambient temperature remains within the 5 deg C to 40 deg C range to prevent sensor drift.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eMounting Requirements\u003c\/strong\u003e: Utilize the integrated VESA bracket interface if elevated mounting is required. Ensure all mounting screws are tightened to meet chassis stability standards.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCable Management\u003c\/strong\u003e: Connect the USB leads directly to the designated HIS terminal ports. Avoid exceeding the maximum USB cable length specifications to prevent data latency or intermittent power supply drops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEarthing and Shielding\u003c\/strong\u003e: While the device is classified as Class I per IEC 61010-1, ensure the HIS terminal workstation is properly grounded to eliminate electrostatic discharge (ESD) risks that could affect the capacitive touch sensors.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49218192769276,"sku":"AIP831-101\/EIM","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/AIP831-1011.jpg?v=1780882796","url":"https:\/\/www.electronicplc.com\/ar\/products\/yokogawa-aip831-101-eim-operation-keyboard","provider":"Electronic PLC","version":"1.0","type":"link"}