{"product_id":"yokogawa-asi533-s00-ss3s0-analog-output-module","title":"Yokogawa ASI533-S00\/SS3S0 Analog Output Module","description":"\u003cp\u003eConfigured for precise signal conversion in CENTUM VP DCS platforms, the \u003cstrong\u003eYokogawa ASI533-S00\/SS3S0\u003c\/strong\u003e (\u003cstrong\u003eASI533-S00\u003c\/strong\u003e Analog Output Module) provides direct electrical execution of control commands to field-mounted actuators and valves.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eASI533-S00 \/ SS3S0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e282 mm (W) x 210 mm (H) x 20 mm (D)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eNot specified (Standard industrial limits apply)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e150 mA (5 V DC); 350 mA (24 V DC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 Channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoad Resistance\u003c\/td\u003e\n\u003ctd\u003e0 to 750 Ohm at 20 mA; 0 to 600 Ohm at 23 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResponse Time\u003c\/td\u003e\n\u003ctd\u003e100 ms (Step response)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUpdate Period\u003c\/td\u003e\n\u003ctd\u003e10 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003e1500 V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control \u0026amp; HART Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe module facilitates seamless integration within Yokogawa distributed control architectures by supporting the 4-20 mA HART loop protocol. Each of the 8 channels features independent galvanic isolation, ensuring channel-to-channel isolation and minimizing common-mode interference during critical valve positioning tasks. The inclusion of HART communication allows for remote configuration and diagnostic data acquisition from smart field devices without interrupting the primary control loop.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003eQ: Does the ASI533-S00 support hot-swapping during active DCS operation?\u003c\/p\u003e\n\u003cp\u003eA: Operation procedures for hot-swapping are subject to the specific base plate and system bus configuration of the CENTUM VP rack. Always ensure the system is in a redundant state if required by the cabinet safety protocol before module extraction.\u003c\/p\u003e\n\u003cp\u003eQ: How is the load resistance affected when operating at the maximum 23 mA output?\u003c\/p\u003e\n\u003cp\u003eA: The allowable load resistance reduces from 750 Ohm to 600 Ohm when the output current reaches the 23 mA threshold to maintain signal linearity and prevent output stage saturation.\u003c\/p\u003e\n\u003cp\u003eQ: Is external power required for the 4-20 mA output loops?\u003c\/p\u003e\n\u003cp\u003eA: The module is designed to provide active current signals. Ensure that field wiring complies with the specified loop resistance limits to prevent voltage drop issues at the actuator interface.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Conditioning:\u003c\/strong\u003e Ensure the mounting surface is vibration-free. Maintain adequate clearance above and below the module to facilitate thermal dissipation of internal components.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eGrounding and Shielding:\u003c\/strong\u003e Terminate cable shields at the designated grounding bar within the cabinet to prevent electromagnetic interference (EMI). Ensure that the shield is not connected to the field device ground to prevent ground loops.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Termination:\u003c\/strong\u003e Secure all I\/O wiring using appropriate torque settings for the terminal block screws. Verify that wire gauges are compatible with the terminal block capacity to ensure mechanical stability under industrial conditions.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eIsolation Integrity:\u003c\/strong\u003e During installation, verify that the 1500 V AC isolation barrier between the field circuits and the internal backplane bus remains intact by preventing moisture ingress or conductive debris accumulation on the connector pins.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49239660626172,"sku":"ASI533-S00\/SS3S0","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/ASI133-H00.jpg?v=1780971136","url":"https:\/\/www.electronicplc.com\/ar\/products\/yokogawa-asi533-s00-ss3s0-analog-output-module","provider":"Electronic PLC","version":"1.0","type":"link"}