{"product_id":"yokogawa-asr133-s00-sr3s0-analog-signal-processing-module","title":"Yokogawa ASR133-S00\/SR3S0 Analog Signal Processing Module","description":"\u003cp\u003eConfigured for multi-range signal conditioning in industrial control networks, the \u003cstrong\u003eYokogawa ASR133-S00\/SR3S0\u003c\/strong\u003e (\u003cstrong\u003eASR133-S00\/SR3S0\u003c\/strong\u003e Analog Signal Processing Module) provides direct physical conversion of voltage and current inputs for integration into DCS processing platforms.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eASR133: Base analog input module identifier.\u003c\/li\u003e\n\u003cli\u003eS00: Standard hardware processing version.\u003c\/li\u003e\n\u003cli\u003eSR3S0: Configuration variant for signal range and integration support.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eASR133-S00\/SR3S0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e100 mm x 90 mm x 25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-10 deg C to +60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e24 VDC (±10%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e8 channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Ranges\u003c\/td\u003e\n\u003ctd\u003e0-10 V, +\/-10 V, 0-20 mA, 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eChannel-to-Channel Isolation and Data Acquisition\u003c\/h3\u003e\n\u003cp\u003eThe ASR133-S00\/SR3S0 utilizes per-channel isolation circuitry to prevent common-mode noise propagation between disparate field loops. This architecture ensures that high-impedance voltage signals and low-impedance current signals remain galvanically isolated from the module backplane, maintaining data integrity during high-speed sampling. The module employs cold junction compensation (CJC) logic where applicable to ensure absolute measurement accuracy in fluctuating thermal environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does this module support field-side power for 4-20 mA loop-powered transmitters?\u003c\/p\u003e\n\u003cp\u003eA: The ASR133-S00\/SR3S0 is designed to receive active or passive signals. Verify the loop configuration requirements; if using 2-wire transmitters, ensure the loop power source is correctly integrated according to the module terminal wiring diagram to avoid over-current conditions.\u003c\/p\u003e\n\u003cp\u003eQ: Can the input range be changed via software configuration for all 8 channels?\u003c\/p\u003e\n\u003cp\u003eA: The ASR133-S00\/SR3S0 supports configurable input ranges, but physical hardware jumpers or specific software parameters must be verified per channel. Consult the engineering system configuration manual for the exact mapping and software-defined range limits.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the control cabinet environment meets the IP20 enclosure rating requirements to prevent moisture or particulate accumulation on the module terminals.\u003c\/li\u003e\n\u003cli\u003eConfirm that the 24 VDC supply voltage is regulated and filtered to prevent power-induced signal noise.\u003c\/li\u003e\n\u003cli\u003eTerminate shielded signal cables at the module shield ground bar to maintain electromagnetic compatibility and reduce induced interference.\u003c\/li\u003e\n\u003cli\u003eVerify the wire stripping length and pressure clamp torque to prevent mechanical stress on the PCB terminals during thermal expansion cycles.\u003c\/li\u003e\n\u003cli\u003ePerform a signal loop calibration check post-installation to ensure that the process variable readings align with the field transmitter outputs.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49219699212540,"sku":"ASR133-S00\/SR3S0","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/ASR133-S00.jpg?v=1780624895","url":"https:\/\/www.electronicplc.com\/ar\/products\/yokogawa-asr133-s00-sr3s0-analog-signal-processing-module","provider":"Electronic PLC","version":"1.0","type":"link"}