{"product_id":"yokogawa-atr8s-10-terminal-block","title":"Yokogawa ATR8S-10 Terminal Block","description":"\u003cp\u003eConfigured for signal termination in process control platforms, the \u003cstrong\u003eYokogawa ATR8S-10\u003c\/strong\u003e (\u003cstrong\u003eATR8S\u003c\/strong\u003e Terminal Block) provides direct physical\/electrical execution of RTD signal connection and surge protection.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eATR8S-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.20 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard panel accessory footprint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003eStandard industrial range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003ePassive device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003ePressure clamp RTD termination with surge absorber\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Connectivity and Transient Protection\u003c\/h3\u003e\n\u003cp\u003eThe ATR8S-10 functions as a dedicated hardware component for RTD input interfacing within CENTUM DCS architectures. The module incorporates integrated surge absorber circuits to mitigate transient voltage spikes that could otherwise propagate through field sensor wiring to the sensitive analog input modules. As a passive termination device, it maintains strict signal impedance characteristics required for high-accuracy RTD measurements. Users must verify the integrity of the pressure clamp connections to ensure consistent contact resistance, as deviations in terminal torque can induce measurement errors in sensitive temperature monitoring loops.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the surge absorber require periodic testing or replacement?\u003c\/p\u003e\n\u003cp\u003eA: The integrated surge protection is a solid-state or component-based passive assembly. While it does not require active configuration, it should be visually inspected for thermal discoloration or physical damage following any significant lightning or power surge event in the field loop.\u003c\/p\u003e\n\u003cp\u003eQ: Is the pressure clamp terminal compatible with both solid and stranded wire?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The pressure clamp design is engineered for standard industrial gauge wiring. Ensure the wire ends are correctly stripped and, if using stranded wire, consider the use of ferrules to prevent fraying and ensure a secure, low-resistance connection.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eMount the ATR8S-10 on a DIN rail or panel surface that provides a secure path to the system earth bus to ensure effective surge dissipation.\u003c\/li\u003e\n\u003cli\u003eRoute RTD field wiring separately from high-voltage AC power lines to prevent induced noise and electromagnetic interference (EMI).\u003c\/li\u003e\n\u003cli\u003eConfirm that the terminal clamp is tightened to the recommended torque specifications to prevent loose connections, which can cause erratic temperature readings.\u003c\/li\u003e\n\u003cli\u003eVerify the signal polarity before final termination to the corresponding DCS input channel.\u003c\/li\u003e\n\u003cli\u003eInspect the terminals for signs of oxidation or moisture ingress, especially in environments with high humidity, to maintain long-term signal stability.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49224518631676,"sku":"ATR8S-10","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/ATR8S-00.jpg?v=1772780842","url":"https:\/\/www.electronicplc.com\/ar\/products\/yokogawa-atr8s-10-terminal-block","provider":"Electronic PLC","version":"1.0","type":"link"}