{"product_id":"yokogawa-f3ct04-on-temperature-control-module","title":"YOKOGAWA F3CT04-ON Temperature Control Module","description":"\u003cp\u003eThe \u003cstrong\u003eYOKOGAWA F3CT04-ON\u003c\/strong\u003e (\u003cstrong\u003eF3CT04-ON\u003c\/strong\u003e) is a high-density, 4-channel temperature control module engineered for the FA-M3 sequence CPU platform. It integrates sophisticated PID and fuzzy logic algorithms to maintain precise thermal regulation in industrial processes.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eF3CT04-ON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.24 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003e14 Thermocouples, 2 DC Voltages\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl Methods\u003c\/td\u003e\n\u003ctd\u003ePID continuous, Time-proportional, Fuzzy logic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Period\u003c\/td\u003e\n\u003ctd\u003e125 ms (1 ch) to 500 ms (4 ch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC, 200 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 to 55 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eAdvanced Thermal Management\u003c\/h3\u003e\n\u003cp\u003eThe F3CT04-ON utilizes advanced control algorithms to handle complex thermal dynamics such as overshoot and lag. By employing \u003cstrong\u003efuzzy logic\u003c\/strong\u003e in conjunction with standard PID control, the module can adapt to process non-linearities, ensuring stable setpoint tracking even in highly variable load environments. The module also features \u003cstrong\u003ebumpless transfer\u003c\/strong\u003e between auto and manual modes, which is essential for protecting delicate heater elements during transition states or emergency manual overrides.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the sampling period be customized for different applications?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the sampling period is dependent on the number of active channels. For high-speed applications, reducing the number of active channels enables a faster sampling rate (down to 125 ms for 1 channel).\u003c\/p\u003e\n\u003cp\u003eQ: Does the module support cold junction compensation (CJC)?\u003c\/p\u003e\n\u003cp\u003eA: Yes, the F3CT04-ON features built-in high-precision CJC for all thermocouple inputs, ensuring accurate temperature readings regardless of ambient terminal block temperature.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eSensor Wiring:\u003c\/strong\u003e Use appropriate thermocouple extension wire of the same type as the sensor to maintain thermoelectric potential accuracy.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding:\u003c\/strong\u003e To mitigate electromagnetic interference (EMI), use shielded, twisted-pair cabling for all input signals and bond the shield to the cabinet ground at a single, dedicated grounding point.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eChannel Configuration:\u003c\/strong\u003e Ensure that the input type (e.g., K-type thermocouple vs. 1-5V DC) is correctly software-configured for each channel prior to connecting sensors to avoid input stage damage.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eThermal Environment:\u003c\/strong\u003e Although the operating range extends to 55°C, mount the module in an area with adequate airflow to prevent internal overheating during sustained full-load operation.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration:\u003c\/strong\u003e Perform periodic checks against a calibrated reference source, especially in pharmaceutical or food-grade applications, to ensure the input accuracy remains within specifications.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49262428946684,"sku":"F3CT04-0N","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/F3CT04-0N2.jpg?v=1783562205","url":"https:\/\/www.electronicplc.com\/ar\/products\/yokogawa-f3ct04-on-temperature-control-module","provider":"Electronic PLC","version":"1.0","type":"link"}