{"product_id":"yokogawa-f3wd64-3p-digital-i-o-module","title":"YOKOGAWA F3WD64-3P Digital I\/O Module","description":"\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eYOKOGAWA F3WD64-3P\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(\u003cstrong\u003eF3WD64\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDigital I\/O Module) operates as a dedicated hardware component for mixed signal processing within FA-M3 programmable logic controller platforms. This module provides direct physical\/electrical execution for 32 digital inputs and 32 transistor sink outputs, facilitating high-density control integration in industrial automation environments.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cp\u003eThe F3WD64-3P is designated by the following configuration attributes:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eF3\u003c\/strong\u003e: Series prefix denoting compatibility with the Yokogawa FA-M3 backplane architecture.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWD\u003c\/strong\u003e: Digital input\/output hybrid function.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e64\u003c\/strong\u003e: 64-point total I\/O capacity (32 input \/ 32 output).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e3P\u003c\/strong\u003e: Transistor sink output configuration with 24 V DC\/12 V DC operating voltage compatibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003ctd\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eModel\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eF3WD64-3P\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eBrand\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eYOKOGAWA\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOrigin\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eJapan\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 (Photocoupler isolated)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOutput Channels\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e32 (Transistor sink type)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eOperating Voltage\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e24 V DC (20.4–26.4 V) \/ 12 V DC (10.2–13.2 V)\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eInput Current\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003e4.1 mA per point\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eIsolation\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003ePhotocoupler\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cspan\u003eMounting\u003c\/span\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cspan\u003eFA-M3 Rack\u003c\/span\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003ePLC Deterministic Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe F3WD64-3P utilizes high-speed backplane bus communication to interface between field devices and the FA-M3 controller logic. Input sampling times are configurable, allowing for precise control of response intervals from 0 microseconds up to 1 millisecond. This deterministic performance ensures that state changes are accurately captured and reflected in the PLC memory, maintaining synchronization across complex control sequences without CPU scan delay.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the output channels handle inductive loads directly?\u003c\/p\u003e\n\u003cp\u003eA: Transistor sink outputs require external flyback diodes when driving inductive loads (such as solenoid valves or relays) to suppress voltage spikes that could damage the internal output transistors.\u003c\/p\u003e\n\u003cp\u003eQ: Is it possible to use different common lines for different groups of inputs?\u003c\/p\u003e\n\u003cp\u003eA: The module architecture utilizes a common line structure of 8 points per common for both inputs and outputs. You must ensure that the voltage reference for each group of 8 channels is consistent with the module's operating voltage range.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEnsure the power supply is within the specified 10.2 V DC to 26.4 V DC range based on the application requirements before wiring to the terminal block.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eObserve the 60% maximum simultaneous input \"ON\" ratio requirement to manage power dissipation and prevent thermal overload within the module housing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse shielded cabling for input signals, particularly those routed near high-noise sources like VFD cables, and terminate the shield to the cabinet protective earth point.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerify the sink-type wiring polarity; the output common must be connected to the negative side of the 24 V DC or 12 V DC power supply to ensure proper load switching.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAfter wiring, use the PLC configuration software to map the specific input and output bits and verify functionality through a manual state-forcing test before full system integration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49257884614908,"sku":"F3WD64-3P","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/F3WD64-3P1.jpg?v=1783388623","url":"https:\/\/www.electronicplc.com\/ar\/products\/yokogawa-f3wd64-3p-digital-i-o-module","provider":"Electronic PLC","version":"1.0","type":"link"}