{"product_id":"yokogawa-fp101-m31-cn0a-b-pressure-sensor","title":"Yokogawa FP101-M31-CN0A*B Pressure Sensor","description":"\u003cp\u003eConfigured for precision pressure monitoring in industrial automation systems, the \u003cstrong\u003eYokogawa FP101-M31-CN0A*B\u003c\/strong\u003e (\u003cstrong\u003eFP101-M31-CN0A*B\u003c\/strong\u003e Pressure Sensor) provides direct physical signal execution via an analog loop.\u003c\/p\u003e\n\u003ch3\u003eSuffix Breakdown \u0026amp; Model Matrix\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eComponent Description\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFP101\u003c\/td\u003e\n\u003ctd\u003eBase Pressure Sensor series (Silicon Micromachining)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e-M31-CN0A*B\u003c\/td\u003e\n\u003ctd\u003eSpecific configuration for process connection and electrical output\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFP101-M31-CN0A*B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYokogawa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eJapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard industrial sensor profile\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eLoop powered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Range\u003c\/td\u003e\n\u003ctd\u003e0-10 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput\u003c\/td\u003e\n\u003ctd\u003e4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e+\/- 0.25% of full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProcess Control Connectivity and Integration\u003c\/h3\u003e\n\u003cp\u003eThe FP101-M31-CN0A*B utilizes silicon micromachining technology to provide stable pressure data within process control architectures. The sensor electronics are engineered to support the 4-20 mA HART loop protocol integration, ensuring that accurate process variables are transmitted with digital diagnostic capability. The internal transducer design features channel-to-channel isolation from the process environment, protecting the gauge from thermal drift and pressure spikes. Furthermore, the unit incorporates cold junction compensation mechanisms where necessary to maintain precision across the entire operating temperature range, ensuring high stability in demanding field instrumentation environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the FP101-M31-CN0A*B be used in explosive atmospheres?\u003c\/p\u003e\n\u003cp\u003eA: Verification of the specific unit's certification label is required. Standard models are typically designed for general industrial use; ensure compliance with local hazardous area zoning requirements before installation.\u003c\/p\u003e\n\u003cp\u003eQ: How is the zero-point calibration maintained in this pressure sensor?\u003c\/p\u003e\n\u003cp\u003eA: The sensor employs an internal resonant silicon design that minimizes long-term drift. Periodic calibration checks should be performed using a certified pressure calibrator to verify the output against the 4-20 mA baseline.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003eEnsure the process connection is free of debris or contaminants before mounting the sensor to prevent clogging of the pressure port.\u003c\/li\u003e\n\u003cli\u003eUtilize appropriate thread sealant or gaskets compatible with the process fluid to ensure a leak-proof connection at the rated pressure range.\u003c\/li\u003e\n\u003cli\u003eTerminate the 4-20 mA output signal using shielded twisted-pair cabling; connect the shield to a single, common earth point to minimize electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eVerify that the ambient temperature at the installation site does not exceed the -40 deg C to +85 deg C operating limit.\u003c\/li\u003e\n\u003cli\u003eSecure the unit using the designated process mounting points to prevent mechanical vibration from affecting the integrity of the pressure measurement.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49245952868604,"sku":"FP101-M31-CN0A*B","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/FP101-M31-CN0AB.jpg?v=1783043696","url":"https:\/\/www.electronicplc.com\/ar\/products\/yokogawa-fp101-m31-cn0a-b-pressure-sensor","provider":"Electronic PLC","version":"1.0","type":"link"}