{"product_id":"yokogawa-ks10-20-a-field-mounted-control-system","title":"YOKOGAWA KS10-20*A Field-Mounted Control System","description":"\u003cp\u003eConfigured for process signal management in industrial automation platforms, the \u003cstrong\u003eYOKOGAWA KS10-20*A\u003c\/strong\u003e (\u003cstrong\u003eKS10-20*A\u003c\/strong\u003e Field-Mounted Control System) provides direct physical\/electrical execution of sensor signal processing and control loop output.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure class=\"table\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eKS10-20*A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eYOKOGAWA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003ejapan\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e200 mm x 150 mm x 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot Specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Types\u003c\/td\u003e\n\u003ctd\u003eUniversal Analog (Current, Voltage, TC, RTD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Types\u003c\/td\u003e\n\u003ctd\u003eRelay, Analog (Current, Voltage)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProtection\u003c\/td\u003e\n\u003ctd\u003eIP66 \/ NEMA 4X\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eDCS Process Control and Connectivity\u003c\/h3\u003e\n\u003cp\u003eThe KS10-20*A supports integration within automated control loops, utilizing 4-20 mA HART loop protocol standards for field device communication. The architecture employs channel-to-channel isolation to preserve signal integrity during analog-to-digital conversion processes. For temperature-based inputs, the system features integrated cold junction compensation (CJC) to ensure measurement accuracy across the specified operating temperature range. The hardware supports fieldbus connectivity, allowing for deterministic data exchange within integrated DCS environments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Does the universal analog input stage require external configuration for RTD versus thermocouple signals?\u003c\/p\u003e\n\u003cp\u003eA: Yes, input mode configuration must be performed via the system software interface to ensure correct bridge excitation and signal scaling for the selected sensor type.\u003c\/p\u003e\n\u003cp\u003eQ: Is the IP66 rating maintained if the cable entries are not sealed according to NEMA 4X standards?\u003c\/p\u003e\n\u003cp\u003eA: No, maintaining the IP66\/NEMA 4X protection rating requires the use of certified cable glands and proper torque application to the housing seals during field installation.\u003c\/p\u003e\n\u003cp\u003eQ: Can the device communicate via multiple protocols simultaneously?\u003c\/p\u003e\n\u003cp\u003eA: The system supports multiple protocols, including MODBUS RTU and PROFIBUS; however, concurrent operation is limited by the active communication port configuration and the system bus architecture.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003col\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnvironmental Mounting\u003c\/strong\u003e: Ensure the unit is mounted on a rigid, vibration-free surface to prevent mechanical stress on internal connectors. Verify that the mounting orientation does not impede heat dissipation within the -20 deg C to 60 deg C range.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eShielding and Grounding\u003c\/strong\u003e: Use shielded twisted-pair cabling for all analog signal runs. Terminate cable shields at the dedicated earth connection point to minimize common-mode noise and prevent electromagnetic interference (EMI) ingress.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eWiring Restrictions\u003c\/strong\u003e: Separate signal-level wiring from high-voltage power conduits by a minimum of 300 mm to maintain signal signal-to-noise ratios.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eEnclosure Integrity\u003c\/strong\u003e: After wiring termination, verify that the front cover gasket is clean and debris-free before tightening the enclosure screws to ensure the specified ingress protection rating.\u003c\/li\u003e\n\u003c\/ol\u003e","brand":"Yokogawa","offers":[{"title":"Default Title","offer_id":49218208268540,"sku":"KS10-20*A","price":99.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0787\/9983\/1292\/files\/KS1-201.jpg?v=1780971137","url":"https:\/\/www.electronicplc.com\/ar\/products\/yokogawa-ks10-20-a-field-mounted-control-system","provider":"Electronic PLC","version":"1.0","type":"link"}